23
Screw connect the threaded end of the hose into the gas
inlet.
After completing the gas connection, ensure that the cooker
is gas sound with a pressure test.
Pressure Testing
The gas pressure can be measured at one of the centre
hotplate burner injectors (not the Wok burner).
The gas pressure can be measured at the injector of one of
the left-hand hotplate burners.
Lift off a burner head. Fit the pressure gauge to the injector.
Turn on and light one of the other hotplate burners.
Turn on the control knob for the burner with the pressure
gauge fitted to let gas through.
See the data badge for test pressures.
Turn off the burners. Make sure that you reassemble the
burner top in the correct way on the burner body.
Electrical Connection
The cooker must be installed by a qualified electrician, in
accordance with all relevant British Standards/Codes of
Practice (in particular BS 7671), or with the relevant national
and local regulations.
Current Operated Earth Leakage Breakers
The combined use of your cooker and other domestic
appliances may cause nuisance tripping, so we
recommend that the cooker is protected on an individual
RCD (Residual Current Device) or RCBO (Residual Current
Breaker with Overload).
IF IN DOUBT, PLEASE CONSULT A SUITABLY QUALIFIED
ELECTRICIAN.
Note:
The cooker must be connected to the correct electrical
supply as stated on the voltage label on the cooker, through
a suitable cooker control unit incorporating a double pole
switch, having a contact separation of at least 3mm in all
poles.
The cooker must not be connected to an ordinary domestic
power point.
Access to the mains terminal is gained by removing the
electrical terminal cover box on the back panel. Connect
the mains cable to the correct terminals for your electrical
supply type
(Fig.7-11
and
Fig.7-12)
. Check that the links are
correctly fitted and that the terminal screws are tight. Secure
the mains cable using the cable clamp.
Hotplate Check
Check each burner in turn (refer to the
‘Hotplate Burners’
section at the front of the instructions).
Grill Check
Turn on the grill control and check that the grill heats up.
ArtNo.000-0010 Electrical connections single-phase
N
L
230Vac 50Hz
6mm
2
N
L
Fig.7-11
ArtNo.000-0011 Electrical connections 3-phase
N
L1 L2 L3
N
L1
L3
L2
3N ac
230/400V 50Hz
6mm
2
Fig.7-12
Summary of Contents for Professional+
Page 30: ...28 ...
Page 31: ...29 ...
Page 32: ... www rangemaster co uk ArtNo 000 0003 CE logo DocNo 000 0001 Back cover Rangemaster ...