31
Technical Data
This cooker is designed for use on either :-
NATURAL GAS (Cat I2H ) at 20mbar or
LP GAS (Cat I3+ ) Butane 29mbar / Propane 37mbar.
NB: THE NATURAL GAS AND LP GAS VERSIONS OF THESE COOKERS ARE DIFFERENT MODELS
AND CANNOT BE CONVERTED FROM ONE GAS FAMILY TO THE OTHER.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION:
Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB/IE
Gas
Electric
Natural Gas
20mbar
220 - 240V 50Hz
Butane
29mbar
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height minimum 893mm maximum 920mm
Overall width
900mm See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas:
Electric
Rp
1
/
2
at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas
L.P. Gas
Injector
Injector
Hotplate
Wok burner
3.5kW
internal 80
3.5kW(246g/h)
internal 54
external 129
external 77
Large Burner
3.0kW
134
3.0kW (210g/h)
87
Medium Burners 1.7kW
109
1.7kW (119g/h)
68
Small Burner
1.0kW
75
1.0kW (70g/h)
51
Main Oven
3.2kW
237
2.9kW (224g/h)
85
Tall Oven (electric)
2.5kW
2.5kW
Grill
2.73kW 190
2.73kW (192g/h) 85
Gas burner inputs based on Gross Calorific Value
Total electrical load 2.6kW approx.