Mounting the hood body
Installation with Bracket
• Hook the hood body onto the bracket
7.1
installed.
• Fix definitively the Hood body onto the bracket by 2 Screws
12t
.
Connections
DUCTED VERSION AIR EXHAUST SYSTEM
When installing the ducted version, connect the hood to the
chimney using either a flexible or rigid pipe ø 150 or 120 mm,
the choice of which is left to the installer.
• To install a ø 120 mm air exhaust connection, insert the re-
ducer flange
9
on the hood body outlet.
• Fix the pipe in position using sufficient pipe clamps (not sup-
plied).
• Remove possible charcoal filters.
9
ø 120
ø 150
Exhausted mode Recommendations and suggestions
Connect the extractor to the exhaust flue through a pipe of minimum diameter 125 mm.
The route of the flue must be as short as possible.
Ideal ducting distance to discharge outlet is maximum of 3 meters straight run, or 2 meters and one 90 de-
gree bend preferably rigid duct.
Maximum ducting distance should be 3 meters, with one 90 degree bend.
For each additional 90 degree bend, the maximum distance is reduced by 1 meter.
If the ducting is not correct it will increase noise and reduce performance.