background image

 
 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

HI-LITE HOOD 

 
 

 

HLTHDS90 

HLTHDS100 
HLTHDS110 

 
 

 

 
 

Instructions Manual 

 

Summary of Contents for HI-LITE HLTHDS100

Page 1: ...HI LITE HOOD HLTHDS90 HLTHDS100 HLTHDS110 Instructions Manual ...

Page 2: ...2 2 INDEX SAFETY INFORMATION 3 CHARACTERISTICS 6 INSTALLATION 7 USE 10 CARE AND CLEANING 11 EN ...

Page 3: ...height please refer to the paragraphs on working dimensions and installation If the instructions for installation for the gas hob specify a greater distance this must be respected Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules For Clas...

Page 4: ...to be adopted for fume discharging it is important to closely follow the regulations pro vided by the local authorities WARNING Before installing the Hood remove the protective films Use only screws and small parts in support of the hood WARNING Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards Do not look directly at the light th...

Page 5: ...els not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of elec trical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential n...

Page 6: ...1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange ø 150 120 mm 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 1 Hood Body Fixing Brackets 7 2 1 2 Upper Chimney Section Fixing Brackets 11 6 Wall Plugs 12a 6 Screws 4 2 x 44 4 12c 6 Screws 2 9 x 6 5 12e 2 Screws 2 9 x 9 5 12t 2 Screws 3 5 x 9 5 22 2 Washers Q ty Documentation 1 Instruction Man...

Page 7: ... Place bracket 7 2 1 on the wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as indicated at 116 mm from the vertical reference line and 320 mm above the horizontal reference line Repeat this operation on the other side Drill ø...

Page 8: ...d body outlet Fix the pipe in position using sufficient pipe clamps not sup plied Remove possible charcoal filters 9 ø120 ø150 Exhausted mode Recommendations and suggestions Connect the extractor to the exhaust flue through a pipe of minimum diameter 125 mm The route of the flue must be as short as possible Ideal ducting distance to discharge outlet is maximum of 3 meters straight run or 2 meters ...

Page 9: ...he grease filters see paragraph Maintenance be ing sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Flue assembly Upper exhaust flue Slightly widen the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Ma...

Page 10: ...ible to change the op erating speed when this function is enabled The respective buttons T1 T2 or T3 or T4 will flash T4 Turns the Motor on at speed three Buttons T1 T4 are on Press and hold for 2 seconds to activate Intensive speed which is timed to run for 6 minutes At the end of this time it will automatically return to the speed set before Suitable to deal with maximum levels of cooking fumes ...

Page 11: ...ing When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CHARCOAL FILTER The filter is not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently for particularly heavy usage Remove the metal grease filters Remove the saturated activated ca...

Page 12: ......

Page 13: ......

Page 14: ......

Page 15: ......

Page 16: ...991 0388 012_ver5 190514 D00001441_04 AGA RANGEMASTER GROUP PLC ...