33
11. Technical Data
THE COOKER IS CATEGORY
: II2H3+.
It is supplied set for group H natural gas. A conversion kit from NG to LP is available for the cooker.
INSTALLER
: Please leave these instructions with the User.
DATA BADGE LOCATION
: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION
: GB, IE.
Connections
Gas
(Rp ½ at rear right-hand side)
Electric
Natural gas
20 mbar
230 / 400 V 50 Hz
Butane
29 mbar
Propane
37 mbar
See the appliance badge for test pressures.
Dimensions
Model
Falcon Deluxe 1092 Dual Fuel
Overall height
minimum 912 mm
maximum 937 mm
Overall width
1092 mm
Overall depth
600 mm (to fascia); 660 mm (including handles)
Minimum height above the hotplate
800 mm
Refer to 'Positioning the Cooker'.
Ratings
Hotplate
Bypass Screw**
Natural Gas 20 mb
LP Gas
Injector
Injector
Centre burner
Large burner
Right-hand front
burner
* This is a special non-counterbored jet. Gas inputs based on Gross Calorific Value.
** The valves in this cooker are fitted with adjustable bypass screws. The cooker is supplied with the bypass screws set for Natural gas. For LPG conversion the
bypass screws must be screwed all the way down.
Hotplate energy saving tips
Oven energy saving tips
Use cookware with a flat base.
Cook meals together, if possible.
Use the correct size cookware.
Keep the pre-heating time short.
Use cookware with a lid.
Do not lengthen cooking time.
Minimise the amount of liquid or fat.
Do not open the oven door during the cooking period.
When liquid starts boiling, reduce the setting.
Do not forget to turn the appliance off at the end of cooking.
Consumption is based on G30.
Summary of Contents for Falcon Deluxe 1092 Dual Fuel
Page 1: ...1092 Deluxe Dual Fuel USER GUIDE INSTALLATION INSTRUCTIONS U103701 12b...
Page 2: ......
Page 4: ...ii...
Page 41: ...37 NOTE...
Page 42: ...38 NOTE...
Page 43: ...39 NOTE...
Page 44: ...Clarence Street Royal Leamington Spa Warwickshire CV31 2AD England www falconworld com...