![Rangemaster Elan 90 Dual Fuel User Manual Download Page 33](http://html1.mh-extra.com/html/rangemaster/elan-90-dual-fuel/elan-90-dual-fuel_user-manual_3678647033.webp)
WARNING – SERVICING TO BE CARRIED OUT ONLY BY AN AUTHORISED PERSON
Disconnect from electricity and gas before servicing. Check appliance is safe when you have finished.
29
29
Stick on Label
Stick the LP gas label over the natural gas part of the
appliance data label.
Pressure Testing
Connect the appliance to the gas supply.
Check the appliance is gas sound.
The gas pressure can be measured at one of the hotplate
injectors (not the wok burner). Lift off a burner head. Fit the
pressure gauge to the jet. Turn on and light one of the other
burners. Turn on and press in the control knob for the burner
with the pressure gauge fitted.
The pressure should be 29 mbar for Butane and 37 mbar for
Propane. After checking the pressure, turn off the taps and
replace the burner head.
Reassemble burner top, making sure it is reassembled in the
correct way on the burner body.
Check operation of all the burners.
Summary of Contents for Elan 90 Dual Fuel
Page 1: ...Elan 90 Dual Fuel Britain s No 1 Range Cooker USER GUIDE INSTALLATION INSTRUCTIONS...
Page 4: ...iv...
Page 36: ...32 Notes...
Page 37: ...33 Notes...
Page 38: ...34 Notes...