35
Technical Data
This cooker is category II
2H3+
It is supplied set for group H natural gas.
A conversion kit from NG to LP gas is packed with the cooker.
INSTALLER: Please leave these instructions with the User.
DATA BADGE LOCATION :
Cooker back, serial number repeater badge below oven door opening.
Country of Destination: GB
Gas
Electric
Natural Gas
20mbar
220 - 240V 50Hz
Butane
29mbar
Propane
37mbar
(See appliance data badge for test pressures)
Dimensions
Overall height
minimum 893mm
maximum 920mm
Overall width
900mm
See ‘Positioning of Cooker’
Overall depth
648mm
Space for fixing
See ‘Positioning of Cooker’
Minimum space above hotplate
650mm
Connections
Gas:
Electric
Rp 1/2 at rear right-hand side
220 - 240V 50Hz
Ratings
Natural Gas
L.P. Gas
Hotplate
Injector
Injector
Wok burner
3.5kW
internal 80
3.5kW (246g/h)
internal 54
external 129
external 77
Large Burner
3.0kW
134
3.0kW (210g/h)
87
Medium Burners
1.7kW
109
1.7kW (119g/h)
68
Small Burner
1.0kW
75
1.0kW (70g/h)
51
Gas burner inputs based on Gross Calorifi c Value
Main Oven
Tall Oven
Ovens
Forced air convection
Forced air convection
2.5kW
2.5kW
Energy effi ciency class on a scale
of A (more effi cient) to G (less effi cient)
A
B
Energy consumption based on standard load
0.85kWh
0.95kWh
Usable volume (litres)
67
53
Size
Large
Medium
Time to cook standard load
38 minutes
49 minutes
Surface area of the grid
1400cm
2
790cm
2
Grill
2.3kW
Warmer
160W
Maximum total electrical load at 230V 7.2kW (approximate total including oven lights, oven fan etc.)