Rane VR2 Data Sheet / Manual Download Page 2

Vc

GND

Vr

100 mA

+5v /

0-5V

REF

1 2 3 4 5

7

6

8

GND

REF

1 2 3 4 5

7

6

8

GND

VERSATILE INPUT PORT

All features & specifications subject to change without notice. PN 12907

©Rane Corporation  10802 47th Ave. W.,  Mukilteo WA 98275-5000  TEL 425-355-6000  FAX 425-347-7757  WEB rane.com

 Wire Types

Variations in wire type do not greatly affect the performance of 

the remote controls. However, a minimum gauge of 22 strand-

ed wire with a flexible jacket is recommended. You may use 

3-conductor unshielded remote control signal cable for shorter 

runs (less than 200 ft.) or 2-conductor (1 pair) shielded remote 

control signal cable (use the shield as the GND return) for longer 

runs (200 to 1000 ft.). The type of wire required is influenced by 

your installation and local electrical codes.

Rane Corporation does 

not

 provide or source cable. Please 

contact your local retail or wholesale outlet, 

not

 the factory. The 

following is a short list of suitable cable types:

CONSOLIDATED ELECTRONIC WIRE AND CABLE

Plenum cable: 

Unshielded remote control signal cable CAT. # 9896

Shielded remote control signal cable CAT. #9877, CAT. #9852

WEICO WIRE & CABLE INC.

Communication and control cable:

Multiconductor, unshielded CAT. #7606

ALPHA

Communication and control cable:

Multiconductor, unshielded CAT. #1175C

BELDEN

Unshielded remote control signal cable CAT. # 88741

Shielded remote control signal cable CAT. # 88723

VR2 All-in-One Block Diagram and Schematic

Wiring shown for VR2 to control VIP pin 1 on 

RPM series units.

Versatile Input Port                 Silkscreen text on VR2

REF Vr

GND GND

VIP pin 1....8 

Vc

20 kΩ, 
linear taper 

GND 

Vc 

CW

Vr 

WARNING: This product may contain chemicals known to the State of California to cause cancer, or birth defects or other reproductive harm.