VERSATILE INPUT PORT
All features & specifications subject to change without notice. PN 12907
©Rane Corporation 10802 47th Ave. W., Mukilteo WA 98275-5000 TEL 425-355-6000 FAX 425-347-7757 WEB rane.com
Wire Types
Variations in wire type do not greatly affect the performance of
the remote controls. However, a minimum gauge of 22 strand-
ed wire with a flexible jacket is recommended. You may use
3-conductor unshielded remote control signal cable for shorter
runs (less than 200 ft.) or 2-conductor (1 pair) shielded remote
control signal cable (use the shield as the GND return) for longer
runs (200 to 1000 ft.). The type of wire required is influenced by
your installation and local electrical codes.
Rane Corporation does
not
provide or source cable. Please
contact your local retail or wholesale outlet,
not
the factory. The
following is a short list of suitable cable types:
CONSOLIDATED ELECTRONIC WIRE AND CABLE
Plenum cable:
Unshielded remote control signal cable CAT. # 9896
Shielded remote control signal cable CAT. #9877, CAT. #9852
WEICO WIRE & CABLE INC.
Communication and control cable:
Multiconductor, unshielded CAT. #7606
ALPHA
Communication and control cable:
Multiconductor, unshielded CAT. #1175C
BELDEN
Unshielded remote control signal cable CAT. # 88741
Shielded remote control signal cable CAT. # 88723
VR2 All-in-One Block Diagram and Schematic
Wiring shown for VR2 to control VIP pin 1 on
RPM series units.
Versatile Input Port Silkscreen text on VR2
REF Vr
GND GND
VIP pin 1....8
Vc
20 kΩ,
linear taper
GND
Vc
CW
Vr
WARNING: This product may contain chemicals known to the State of California to cause cancer, or birth defects or other reproductive harm.