Rane VR2 Data Sheet / Manual Download Page 1

DATA SHEET / MANUAL

VR2

VOLUME REMOTE

Description

The VR2 mounts in a standard US electrical box and can be 

covered with a Decora plate. It contains a linear taper potentiom-

eter with a single Euroblock screw terminal for each of the pot’s 

three conductors, the Vr terminal, the Vc wiper terminal, and the 

ground terminal.

Connection

Turn the power to the unit off until all connections are made. 

Con-

nect the VR2's  control voltage Vc (wiper) connection(s) first. 

Then connect the voltage reference - “Vr” on the VR2 (“REF” 

terminal on a RPM unit). Connect the GND (ground) terminal 

last. Double and triple check your wiring before applying power 

to the MA 4 or RPM since improper wiring can and will cause 

permanent, irreparable damage to the VR2, requiring replace-

ment of the remote. 

Such damage is not covered by Rane's war-

ranty

; checking the wiring is easier than a second trip to the job 

site with another remote.

Euroblocks

Be sure to note the wire color of each input in order to facilitate 

correct wiring to the controlled unit. If the ground or shield wire 

is left shorter, it acts as a strain relief for the other wires. Con-

nect each wire to the 3-pin connector by fully inserting it in the 

correct socket and tightening the screw. Make sure wires are free 

of nicks and that the cable jacket is stripped back sufficiently 

to allow it to lie in the electrical box with the remote assembly 

inserted.

Voltages

Turn the power to the unit 

off 

until all connections are made. It 

is important to ensure that the Remote Ports are not subjected 

to sustained voltages outside the range of 0 to 5 volts DC or 

high levels of static. Inputs are protected, however, caution is the 

better part of... you know. It is a good idea to install the wiring, 

connect it to the Remote and then make the final connections at 

the Remote Port.

Do 

not

 short the Vref pin to ground. This pin is current 

limited, however, excess heat is generated in the 5 volt supply if a 

short occurs. 

Never subject the Vr pin to voltages above 5 volts.

Remote Mounting

The VR2 remote assembly mounts in a standard U.S. electrical 

box with a minimum depth of 2.25" (5.5 cm). Use the flat head 

#6 screws supplied with the kit to mount the remote assembly 

and silk-screened front panel to the electrical box.

Install the knob so that the line on the knob is properly 

aligned with the silk-screening on the front panel of the remote. 

Install any Decora plate of your choice. For a secured installa-

tion, you may wish to leave the knobs off and use a blank Decora 

plate to cover the remote after adjustment.

Vc

GND

Vr

4

0

2

6

8

10

LEVEL

Decora plate cover, not supplied.