Rane SM 82S User Manual Download Page 30

WARRANTY PROCEDURE - Only Valid in the USA

NOTICE! You must complete and return the warranty card or register your 

product online to extend the Warranty from 2 years to 3 years!

TO VALIDATE YOUR EXTENDED WARRANTY: Use the postcard that came in the box with your unit, or go to 

www.rane.com

 and 

click on 

New Product Registration

. Fill out the warranty completely, being sure to 

include the model and serial number

 of the unit 

since this is how warranties are tracked. If your Rane product was purchased in the USA, mail the completed card or register online with 

to Rane Corporation within 10 days from the date of purchase. 

If you purchased the product outside the USA you must file your 

warranty registration with the Rane Distributor in that country.

 It is advised that you keep your bill of sale as proof of purchase, 

should any difficulties arise concerning the registration of the warranty card. 

NOTICE:

 IT IS NOT NECESSARY TO REGISTER IN 

ORDER TO RECEIVE RANE CORPORATION’S STANDARD TWO YEAR LIMITED WARRANTY.

WARRANTY REGISTRATION is made and tracked by 

model and serial numbers only

, not by the purchaser’s or owner’s name. 

Therefore any warranty correspondence or inquires 

must

 include the model and serial number of the product in question. Be sure to fill 

in the model and serial number in the space provided below and keep this in a safe place for future reference.

WARRANTY SERVICE MUST BE PERFORMED ONLY BY AN AUTHORIZED RANE SERVICE FACILITY LOCATED IN 

THE COUNTRY WHERE THE UNIT WAS PURCHASED, OR (if product was purchased in the USA) AT THE RANE FACTORY 

IN THE USA. If the product is being sent to Rane for repair, please call the factory for a Return Authorization number. We recommend 

advance notice be given to the repair facility to avoid possible needless shipment in case the problem can be solved over the phone. 

UNAUTHORIZED SERVICE PERFORMED ON ANY RANE PRODUCT WILL VOID ITS EXISTING FACTORY WARRANTY.

FACTORY SERVICE

If you wish your Rane product to be serviced at the factory, 

it must be shipped fully insured, in the original packing box or equivalent

This warranty will 

not

 cover repairs on products damaged through improper packaging. If possible, avoid sending products through the 

mail. Be sure to include in the package:

1.  Complete return street shipping address (P.O. Box numbers are 

not

 acceptable).

2.  A detailed description of any problems experienced, including the make and model numbers of any other system equipment.

3.  Remote power supply, if applicable.

Repaired products purchased in the U.S. will be returned prepaid freight via the same method they were sent to Rane. Products purchased 

in the USA, but sent to the factory from outside the USA 

must

 include return freight funds, and the sender is fully responsible for all 

customs procedures, duties, tariffs and deposits.

In order to qualify for Rane’s one year extended warranty (for a total of 3 

years parts and labor), the warranty must be completely filled out and sent to 

us immediately. Valid in USA only.

We recommend you write your serial number here in your owners 

manual and on your sales receipt for your records.

SERIAL NUMBER:______________________________________PURCHASE DATE:__________________________________

©Rane Corporation  10802 47th Ave. W.,  Mukilteo WA 98275-5000  TEL 425-355-6000  FAX 425-347-7757  WEB www.rane.com

Warranty-2

108360

Summary of Contents for SM 82S

Page 1: ...SM82S STEREO LINE MIXER CONTENTS in order of appearance Important Safety Instructions SM82S Manual SM82S Data Sheet Sound System Interconnection Schematics Warranty Declaration of Conformity 22372...

Page 2: ...ain readily operable To completely disconnect this apparatus from the AC mains disconnect the power supply cord plug from the AC receptacle 16 This apparatus shall be connected to a mains socket outle...

Page 3: ...accessible Pour d connecter totalement l appareil du secteur d branchez le c ble d alimentation de la prise secteur 16 Cet appareil doit tre branch une prise terre avec protection 17 Quand il est bra...

Page 4: ......

Page 5: ...e outputs no matter which mode you are using If a mono connector is used insert ing it into the output will short the ring to ground and could conceivably cause a small amount of distortion to be plac...

Page 6: ...he R 4 Input SEND Level controls determine the amount of Post Fade stereo Input is fed to the Loop Send buses Each Input s stereo SEND is summed on this bus and is available at the respective LEFT and...

Page 7: ...eo Inputs mono signal may be connected to the LEFT input to obtain two channel mono operation 6 MAIN EXPAND OUTPUT This TRS stereo Tip left Ring right Output jack connects one SM82S to another for the...

Page 8: ...esired to the Left and Right Outputs A stereo SEND control adjusts the amount of each Input routed to the Loop Output All eight stereo Inputs are simultaneously adjusted for stereo placement by the OU...

Page 9: ...evel control slider and a left to right Balance control slider When a single mono input is used the Balance control acts as a pan pot The aux return section provides a rotary Return Level control and...

Page 10: ...ain Active Balanced Unbalanced Differential line drivers Loop Send Unbalanced Expand Unbalanced Output Connectors TRS Output Gain Range Off to 6 2 dB Unbalanced Frequency Response 20 Hz 20 kHz 3 dB TH...

Page 11: ...uts as well as the loop send output shall be configured such that plugging only into the left input or output will mono the system Each stereo input shall have a rotary ganged level control with a ran...

Page 12: ...Left Input Jack automatical ly routes this signal to the Right channel so an equal Left Right signal is summed into the mains Similarly connecting only to the Left Loop Send output gives you an equal...

Page 13: ...rconnections Grounding and EMC practices Shields of connectors in audio equipment containing active circuitry Rane s policy is to accommodate rather than dic tate However this document contains sugges...

Page 14: ...al grounding system improperly thus creating balanced equipment that is not immune to the cabling s noise currents This is one reason for the bad reputation sometimes given to bal anced interconnect A...

Page 15: ...n Figure 1b Recommmended practice CASE COMMON WRONG PRACTICE RECOMMENDED PRACTICE OPTIONAL CASE 1 2 3 3 1 2 CHASSIS GROUND SIGNAL GROUND CHASSIS GROUND CHASSIS GROUND Not using signal ground is the mo...

Page 16: ...consistent success indicates this and other acceptable solutions to RF issues exist though the increasing use of digital and wireless technology greatly increases the possibility of future RF problem...

Page 17: ...eferences 1 Neil A Muncy Noise Susceptibility in Analog and Digi tal Signal Processing Systems presented at the 97th AES Convention of Audio Engineering Society in San Fran cisco CA Nov 1994 2 Groundi...

Page 18: ...20 24 24 19 18 17 B B B B A A A A A A FEMALE BALANCED XLR NOT A TRANSFORMER NOR A CROSS COUPLED OUTPUT STAGE FEMALE BALANCED XLR EITHER A TRANSFORMER OR A CROSS COUPLED OUTPUT STAGE BALANCED TRS NOT A...

Page 19: ...RED SHIELD RED SHIELD SHIELD RED RED BLACK N C N C N C RED BLACK RED SHIELD N C BLACK RED BLACK RED 3 NC 2 RED 1 SHIELD 2 RED 1 SHIELD 3 BLACK 2 RED 1 NC 3 BLACK 2 RED 1 NC 3 BLACK 2 RED 1 SHIELD SHIE...

Page 20: ...3 BLACK 2 RED 1 SHIELD 3 BLACK 2 RED 1 SHIELD 3 BLACK 2 RED 1 SHIELD SHIELD BLACK SHIELD RED BLACK SHIELD RED BLACK RED SHIELD SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIELD BLACK RED SHIE...

Page 21: ......

Page 22: ......

Page 23: ...NPUT 4 10 0k R45 10 0k R48 D7 4148 D9 4148 90 9k R47 1 50v C56 GND GND J5B J5A Z9 2200pF Z10 2200pF C42 4 7 16v C43 4 7 16v C50 4 7 16v C51 4 7 16v 2 1 3 R32A 100kA 5 4 6 R32B 100kA 10 0k R39 10 0k R4...

Page 24: ...v C100 4 7 16v C101 4 7 16v 2 1 3 R75A 100kA 5 4 6 R75B 100kA 10 0k R81 10 0k R82 4580 8 3 2 1 4 U8A 4580 5 6 7 U8B GND GND GND GND 15 15 47pF C104 47pF C105 20 0k R85 20 0k R77 C96 47 50v GND C97 47...

Page 25: ...1 J11 T 1A 250V F3 0 0022 X1Y2 C195 0 0022 X1Y2 C196 20mH 1 2 4 3 T1 0 33 C197 4 3 1 2 D33 DF06M 0 001 C200 0 001 C199 0 0022 X1Y2 C201 H6 GNDP VIPER50 1 2 5 4 3 Vdd OSC DRAIN S COMP U38 10 0k R144 60...

Page 26: ...GNDS GNDS 7 BAL_RIGHT 7 BAL_LEFT 2 1 3 R168A 100kA 5 4 6 R168B 100kA 2 1 3 R164A 100kMN 5 4 6 R164B 100kMN 20 0k R184 20 0k R178 20 0k R180 20 0k R179 GNDS GNDS GNDS 8 BAL_RIGHT 8 BAL_LEFT 2 1 3 R186A...

Page 27: ...0k R209 GNDS 10 0k R201 D37 RED 072 3 2 1 8 4 U18A 15S OL 20 0k R204 10 0k R210 GNDS 10 0k R203 D30 RED 072 5 6 7 U18B 15S OL 15S 15S 20 0k R206 10 0k R211 GNDS 10 0k R205 D31 RED 072 3 2 1 8 4 U19A...

Page 28: ......

Page 29: ...ECTS IN MATERIAL OR WORKMANSHIP THE SPECIFIC PERIOD OF THIS LIMITED WARRANTY SHALL BE THAT WHICH IS DESCRIBED TO THE ORIGINAL RETAIL PURCHASER BY THE AUTHORIZED RANE DEALER OR DISTRIBUTOR AT THE TIME...

Page 30: ...IN THE USA If the product is being sent to Rane for repair please call the factory for a Return Authorization number We recommend advance notice be given to the repair facility to avoid possible need...

Page 31: ...ve and EMC direc tive in the event that the equipment is modified without written consent of the manufacturer This declaration of conformity is issued under the sole responsibility of Rane Corporation...

Page 32: ...CED LOOP SEND UNBALANCED MAIN EXPAND INPUT LOOP EXPAND INPUT LEFT MONO RIGHT LEFT MONO RIGHT LEFT MONO RIGHT LEFT MONO RIGHT LEFT MONO RIGHT LEFT MONO RIGHT LEFT RIGHT RIGHT LEFT MONO LOOP RETURN UNBA...

Reviews: