background image

Appendix 1. Switches / Lights Connector Logic

Appendix 2. NM 1 MIB

--
-- RANE-NM1-MIB-V1.my
-- MIB generated by MG-SOFT Visual MIB Builder Version 4.0 Build 341
-- Thursday, May 20, 2004 at 17:53:02
--

 

RANE-NM1-MIB-V1 DEFINITIONS ::= BEGIN

  IMPORTS
   mfgExtensions
    FROM 

PEAKAUDIO-MIB

   OBJECT-TYPE
    FROM 

RFC-1212

   Counter
    FROM 

RFC1155-SMI;

--
-- Node definitions
--

--  Node definitions
-- 
  -- 

1.3.6.1.4.1.2680.1.2.7

 

 

rane OBJECT IDENTIFIER ::= { mfgExtensions 7 }

  -- 

1.3.6.1.4.1.2680.1.2.7.3

 

 

NM1 OBJECT IDENTIFIER ::= { rane 3 }

  -- 

1.3.6.1.4.1.2680.1.2.7.3.1

  micPreampGain 

OBJECT-TYPE

   SYNTAX 

INTEGER 

(10..65)

   ACCESS 

read-write

   STATUS 

mandatory

   DESCRIPTION
 

 

 

 

"Gain through the mic pre-   

 

 

 

 

amplifier stage. Gain can be   

 

 

 

 

adjusted in 1 db increments   

 

 

 

 

in the range 10dB through   

    65dB."
 

 

 

DEFVAL { 10 }

 

 

 

::= { NM1 1 }

  -- 

1.3.6.1.4.1.2680.1.2.7.3.2

  microphoneMute 

OBJECT-TYPE

   SYNTAX 

INTEGER

   ACCESS 

read-only

   STATUS 

mandatory

   DESCRIPTION
 

 

 

 

"State of the microphone    

    mute. 
    0 

unmuted

    1 

muted"

 

 

 

::= { NM1 2 }

Q

1
2

3

1
2

3

Cough

Button

Talk

Button

Override

Button

Privacy

Button

*Ground pins on the DB-15

connector are 6, 7, 8, 9, &10.

Pins 3 & 13 on the DB-15

connector are no-connects.

See the MIB for

explanation of variables.

*

*

*

*

*

*

*

*

Pin 2

Pin 12

Pin 11

Pin 14

Pin 15

Pin 1

Pin 4

Pin 5

Internal pull-up,

debounce and

ESD protection.

Internal pull-up,

debounce and

ESD protection.

Internal pull-up,

debounce and

ESD protection.

Internal pull-up,

debounce and

ESD protection.

SNMP: talkToggle (read-write)

SNMP: talk

(read)

SNMP: override (read-only)

SNMP: privateMode (read)

SNMP: cough (read-only)

SNMP: microphoneMute

(read-only)

Flip-Flop

Toggle

Toggle

Q

Flip-Flop

Toggle

Toggle

SNMP: coughDisable (read-write)

SNMP: overrideDisable

(read-write)

SNMP: talk (write)

0 = clear flip-flop

1 = set flip-flop

“edge-triggered”

SNMP: privateMode (write)

0 = clear flip-flop

1 = set flip-flop

“edge-triggered”

SNMP: privateModeToggle (read-write)

Reviews: