Rane MA 4 Datasheet Download Page 2

Data Sheet-2

MA 4

MULTICHANNEL AMPLIFIER

Specifications

Parameter

Specification

Conditions/Comments

Input impedance

10 kΩ

Each leg, differential, 1 kHz

Maximum input

+22 dBu

Sensitivity range/resolution

+22 to +4 dBu

256 steps

Remote level control range/resolution

Attenuate only; 0 dB to –80 dB

Audio taper response, 256 steps

Fault flag in/out

Active 5V high-side drive, passive pull down.

NO Fault = +5V; Fault = 0V

Limiter

Oversampled instantaneous attack

3 dB per second decay

..........Load compensated

Limit set for 7.5 amps peak

Based on load Z

Compressor

50 ms rms detector

Threshold relative to limiter

..........Threshold

10 dB re peak dBFS

Rear panel dipswitch on/off

..........Attack

1.5 second

..........Decay

3 dB per second

..........Knee Span

10 dB

Expander

Select on rear panel

rms detector

..........Threshold

-70 dBFS

..........Attack

50 ms

Gain reduction release time constant

..........Decay

10 dB per second

Rate of gain reduction

High-pass filter

12 dB per octave, Butterworth

20, 40, 60, 80 Hz dipswitch select

Load sensing

2 to 16Ω normal

Green Load indicator 

on

..........Low load detect

Below 2Ω is low

Green Load indicator 

flashing

..........High load detect

Above 16Ω is high

Green Load indicator 

off

..........Min average power

3.3 watts average required for good load estimate

Output
..........Power

100 watts

3 to 8 Ω

..........Frequency response

20 Hz to 20 kHz

+0, -3 dB

..........Dynamic range

>90 dB

A-weighted, typical

..........THD+N

0.1% typ

100 watts into 4Ω, 20-20 kHz

..........Clock fundamental

310 kHz

<10 mV residual

..........Relay switching

Turn on mute, fault protection, redundancy switching

Fan cooling

Temperature controlled, variable speed

Intake left side, exhaust right side

Heat load in Btu/hr

100 / 240 volts AC 50/60 Hz

..........Standby

10.2 / 13.3

..........Run mode, no signal

112.3 / 95.5

..........All channels driven

167 / 139

pink noise, average ⅛

th

 power, 4:1 crest

AC Mains

100 to 240 VAC

±10%, 50 or 60 Hz

PFC

100 kHz boost

DC/DC

200 kHz forward

Unit: Conformity

FCC, CULUS

..........Construction

All Steel

..........Size

1.75"H x 19"W x 9.25"D

(4.4 cm x 48.3 cm x 23.5 cm)

..........Weight:

8 lb

(3.6 kg)

Shipping: Size 

4.5" x 20.3" x 13.75"

(11.5 cm x 52 cm x 35 cm)

..........Weight:

11 lb

(5 kg)

All specifications typical unless otherwise noted.

Summary of Contents for MA 4

Page 1: ...power factor corrected supplies A long list of unique features ranging from constant load power to built in automatic redundancy switching to advanced dynamics control qualify the MA 4 for the most de...

Page 2: ...0 40 60 80 Hz dipswitch select Load sensing 2 to 16 normal Green Load indicator on Low load detect Below 2 is low Green Load indicator flashing High load detect Above 16 is high Green Load indicator o...

Page 3: ...Hz HIGH PASS filters are provided The setting affects all channels Filters are 12 dB per octave Butterworth alignment 8 Each channel is set for MASTER or SLAVE operation Master channels write Fault Fl...

Page 4: ...L U A F D A O L Y D A E R P X E B d 3 B d 6 B d 2 1 B d 4 2 T I M I L P M O C T L U A F D A O L Y D A E R P X E 4 H C 3 H C 2 H C 1 H C P S D T S O H D N G Y T I V I T I S N E S 4 H C 3 H C 2 H C 1 H...

Page 5: ...2 Z H 0 4 z H 0 6 z H 0 8 E D O M V 8 0 O T V 0 0 Y B D N A T S V 0 3 O T V 2 2 E T U M V 5 5 O T V 2 4 N O 1 M 2 M 3 M 4 M 1 M 2 M 3 M 4 M E S N E S Y L P P U S 5 2 R E T I M I L K A E P DETECT RMS...

Page 6: ...selection of 20 40 60 or 80 Hz highpass 2nd order Butterworth filters Load sensitive limiter circuits shall prevent clipping and the associated loss of speech intelligibility A front panel LED shall i...

Page 7: ...Rane VR 2 or 20 k pot HIGH PASS 20Hz 40Hz 60Hz 80Hz ON 4 REMOTE LEVEL 4 4 FLAG 3 2 1 FAULT Vr Vc Vr Vc Vr Vc Vr Vc 3 2 1 MASTER SLAVE COMP 4 3 2 1 1 2 3 4 Vr Vc Vr Vc Vr Vc Vr Vc INPUTS MODE 13 22 dBu...

Page 8: ...P 4 3 2 1 1 2 3 4 Vr Vc Vr Vc Vr Vc Vr Vc INPUTS MODE 13 22 dBu SENSITIVITY 4 3 13 22 dBu SENSITIVITY 4 2 13 22 dBu SENSITIVITY 4 1 13 22 dBu SENSITIVITY 4 EXP ON 3 INT EXT LOAD 2 INT EXT LOAD 1 INT E...

Reviews: