Remote Mounting and Wiring
The LRS4 remote assembly mounts in a standard U.S. electrical
box with a minimum depth of 2.5" [6.4 cm]. Turn the power
to the unit
off
until all connections are made. It is important
to ensure that the Remote Ports are not subjected to sustained
voltages outside the range of 0 to 5 volts DC or high levels of
static. The device inputs are protected, however you can save a lot
of time by taking this precaution. It is a good idea to install the
wiring, connect it to the Remote and then make the final con-
nections at the unit.
When wiring to Euroblocks, a minimum wire gauge of 22 is
preferred for reliability. If the ground or shield wire is left shorter,
it acts as a strain relief for the other wires. Cable with a flexible
jacket is easier to use and less likely to damage the connections.
Be sure to note the wire color of each input in order to facilitate
correct wiring to the unit. Make sure wires are free of nicks and
that the cable jacket is stripped back sufficiently to allow it to lie
in the electrical box with the remote assembly inserted. Connect
each wire to the 5-pin connector by fully inserting it in the cor-
rect socket and tightening the screw.
Use the flat head #6 screws supplied with the kit to mount
the remote assembly and silkscreened front panel to the electrical
box. Install the Decora plate of your choice (not included).
Wire Types
Variations in wire type do not greatly affect the performance
of the remote controls. However, 22-gauge stranded wire with
a flexible jacket is recommended. You may use 3-conductor
unshielded remote control signal cable for shorter runs (less than
200 feet [60 meters]) or 2-conductor (1 pair) shielded remote
control signal cable (use the shield as the GND return) for longer
runs (200 to 1000 feet [60 to 300 meters]). The type of wire
required is influenced by your installation and local electrical
codes.
Rane Corporation does
not
provide or source cable. Please
contact your local retail or wholesale outlet,
not
the factory. The
following is a short list of suitable cable types:
CONSOLIDATED ELECTRONIC WIRE AND CABLE
Plenum cable:
Unshielded remote control signal cable CAT. #9896
Shielded remote control signal cable CAT. #9877 or #9852
WEICO WIRE & CABLE INC.
Communication and control cable:
Multiconductor, unshielded CAT. #7606
ALPHA
Communication and control cable:
Multiconductor, unshielded CAT. #1175C
BELDEN
Unshielded remote control signal cable CAT. #88741
Shielded remote control signal cable CAT. #88723
Block Diagram / Schematic
Note: Older Rane units may be marked differently. Consult this
chart if your unit does not have VR and VC terminals.
2
3
1k
1
4
5 kΩ
5 kΩ
5 kΩ
5 kΩ
1k
1k
1k
GND
CP 64
LRS 4
CP 52
DA 26
MP 44
RPM *
VR
VR1or2
VR
REF
VR
REF
VC
V1or2
VC
VC
VC
1-8
GND
VR
VC
GND
GND