Remote Mounting and Wiring

The LRS4 remote assembly mounts in a standard U.S. electrical 

box with a minimum depth of 2.5" [6.4 cm]. Turn the power 

to the unit 

off 

until all connections are made. It is important 

to ensure that the Remote Ports are not subjected to sustained 

voltages outside the range of 0 to 5 volts DC or high levels of 

static. The device inputs are protected, however you can save a lot 

of time by taking this precaution. It is a good idea to install the 

wiring, connect it to the Remote and then make the final con-

nections at the unit.

When wiring to Euroblocks, a minimum wire gauge of 22 is 

preferred for reliability. If the ground or shield wire is left shorter, 

it acts as a strain relief for the other wires. Cable with a flexible 

jacket is easier to use and less likely to damage the connections. 

Be sure to note the wire color of each input in order to facilitate 

correct wiring to the unit. Make sure wires are free of nicks and 

that the cable jacket is stripped back sufficiently to allow it to lie 

in the electrical box with the remote assembly inserted. Connect 

each wire to the 5-pin connector by fully inserting it in the cor-

rect socket and tightening the screw.

Use the flat head #6 screws supplied with the kit to mount 

the remote assembly and silkscreened front panel to the electrical 

box. Install the Decora plate of your choice (not included).

Wire Types

Variations in wire type do not greatly affect the performance 

of the remote controls. However, 22-gauge stranded wire with 

a flexible jacket is recommended. You may use 3-conductor 

unshielded remote control signal cable for shorter runs (less than 

200 feet [60 meters]) or 2-conductor (1 pair) shielded remote 

control signal cable (use the shield as the GND return) for longer 

runs (200 to 1000 feet [60 to 300 meters]). The type of wire 

required is influenced by your installation and local electrical 

codes.

Rane Corporation does 

not

 provide or source cable. Please 

contact your local retail or wholesale outlet, 

not

 the factory. The 

following is a short list of suitable cable types:

CONSOLIDATED ELECTRONIC WIRE AND CABLE

Plenum cable:

Unshielded remote control signal cable CAT. #9896

Shielded remote control signal cable CAT. #9877 or #9852

WEICO WIRE & CABLE INC.

Communication and control cable:

Multiconductor, unshielded CAT. #7606

ALPHA

Communication and control cable:

Multiconductor, unshielded CAT. #1175C

BELDEN

Unshielded remote control signal cable CAT. #88741

Shielded remote control signal cable CAT. #88723

Block Diagram / Schematic

Note: Older Rane units may be marked differently. Consult this 

chart if your unit does not have VR and VC terminals.

2

3

1k

1

4

5 kΩ

5 kΩ

5 kΩ

5 kΩ

1k

1k

1k

GND

CP 64

LRS 4

CP 52

DA 26

MP 44

RPM *

VR

VR1or2

VR

REF

VR

REF

VC

V1or2

VC

VC

VC

1-8

GND

VR

VC

GND

GND

Reviews: