Manual-

FRONT PANEL DESCRIPTION

POWER switch & indicator:

 The yellow LED lights any time this switch is closed and power is, in fact, actually flowing into the 

GE 60.

Filter level controls

 set the individual levels for each of the constant-Q filters. Their range is ±12 dB, and the grounded center-de-

tent design ensures individual filters are off and bypassed when positioned to their centers.

LOW CUT FILTER control

 sets the corner frequency (–3 dB point) for the low cut filter (high pass). Adjustable from 10 Hz to 

250 Hz.

HI CUT FILTER control 

sets the corner frequency (–3 dB point) for the high cut filter (low pass). Adjustable from 3 kHz to 40 

kHz.

Channel LEVEL control

 sets the overall desired gain through the unit. The range is from Off to +8 dB for balanced use, or from 

Off to +2 dB for unbalanced operation. Unity gain is at approximately “8” (balanced) or “10” (wide open, unbalanced). Using the 

highest setting (without lighting the 

OL

 indicator) yields the best signal-to-noise performance.

OVERLOAD indicator

 LED monitors all critical points for excessive signal levels. It lights whenever these levels exceed 4 dB 

below clipping. Occasional flickering is normal; however, it should not be allowed to light steadily.

BYPASS switch & indicator:

 This pushbutton switch activates the “hard-wire” bypass function. When engaged (red 

BYPASS

 

LED 

on

), all three pins of the 

INPUT

 connectors directly connect to the same pins on the 

OUTPUT

 connectors (hard-wired). 

Engaging this switch converts the GE 60 into a relatively expensive patch cord, but one with pretty lights.