REAR PANEL DESCRIPTION

1. AUDIO INPUT TERMINALS. 

Attach balanced input lines to the “+”, “–”, and

SHIELD GROUND #6 terminals. To run the FVL 22 unbalanced, attach the
positive lead to the “+” terminal and leave the “–” terminal open.

2.AUDIO OUTPUT TERMINALS. 

Attach balanced output lines to the “+”, “–”,

and SHIELD GROUND #6 terminals. To run the FVL 22 unbalanced, attach the
positive lead to the “+” terminal and leave the “–” terminal open.

3. PATCH I/O JACK

 provides a convenient method to use the FVL 22 as an

external processor for a mixer or other device with tip = send, ring = return insert
points. Use a two conductor shielded Tip-Ring-Sleeve cable. Use of the PATCH I/
O jack automatically disconnects the terminal strip input.

4. VOLTAGE CONTROL.

 These terminals are your gateway to the VCA control

circuitry. The VREF terminal provides a precise 10VDC reference voltage output.
The V1 terminal accepts a given voltage (+5 to 24VDC), which when properly
calibrated, provides maximum attenuation. As this voltage 

decreases

, the audio

level 

increases

. Decrease this voltage with whatever method suits your applica-

tion (Potentiometer, switch, or voltage ramp—see back page for details).

5. GROUND LIFT SWITCH

 provides the ability to separate chassis ground and

signal ground. Normally, this switch should be in the LIFT position. In some
circumstances it may be necessary to move it to the opposite position to eliminate
stubborn hum and buzz problems. See the CHASSIS GROUNDING note below
for details. 

CAUTION:

 If you are tempted to try moving this switch with your

amplifier levels turned up, 

don’t be. Always turn your amplifier levels down

before changing your grounds around

 and then bring them up slowly.

6. POWER INPUT CONNECTOR.

 This is the spot where the “appropriate power

supply” connects. Again, for a complete definition of the power supply, look to
the first page for information concerning the source nearest you.

7. GROUND CONNECTOR. 

Since the FVL 22 is powered from a remote AC

power supply which does not carry chassis ground through to the grounding pin
of the AC cord, this 6-32 screw has been provided in case your system does not
have another earth grounding means such as through rack rails, etc. Its use or
disuse should be determined by your specific application.

Summary of Contents for FVL 22

Page 1: ... an approved Rane AC Power supply to the thing that looks like a red telephone jack on the rear of the FVL 22 This is an AC power input and requires special attention if you do not have a power supply exactly like the one originally packed with your unit Rane models FRS 8 RAP 10 or VC 18 power supplies are acceptable as well Please see the full explanation of power supply requirements elsewhere in...

Page 2: ...ckwise untiltheCAL indicatorcomeson 4 VOLTAGECALIBRATIONADJUST Usethisscrewdriver adjust control to set the VCA circuitry calibration when the external voltage at V1 is set to its maximum level 5 LIMITTHRESHOLDLED WhenthisLEDilluminates thepreset level threshold of the limiter has been exceeded 6 LIMITERADJUST Rotatethisscrewdriver adjustcontroltocalibrate the point at which the output limits The ...

Page 3: ...Decreasethisvoltagewithwhatevermethodsuitsyourapplica tion Potentiometer switch orvoltageramp seebackpagefordetails 5 GROUND LIFT SWITCH providestheabilitytoseparatechassisgroundand signal ground Normally this switch should be in the LIFT position In some circumstances it may be necessary to move it to the opposite position to eliminate stubbornhumandbuzzproblems SeetheCHASSISGROUNDINGnotebelow fo...

Page 4: ...edence The audio level can only be controlled when it is under the threshold of the limiter i e when the LIMIT indicator is off Thelimiterhasanadditionalfeature AUTO SLAVE This switch ties the control circuitry of the two limiters together If either Channel s level exceeds its set threshold bothChannelslimitthesameamount Thisretainsspectral balanceforbi ampedloudspeakersorpreservedstereoimage inst...

Reviews: