Rane DC 22S Instruction Manual Download Page 10

·                                ·

(Signature)

January 15, 2009

(Date)

Mukilteo WA, USA

(Place)

Compliance Engineer

(Position)

Declaration of Conformity

Application of  

Council Directive(s):

2001/95/EC

2002/96/EC

2004/108/EC

2006/95/EC

2011/65/EU

Manufacturer:

Rane Corporation

10802 47th Avenue West

Mukilteo WA 98275-5000  USA 

This equipment has been tested and found to be in compliance with all applicable standards and regulations applying to the 

EU’s Low Voltage (LV) directive 2006/95/EC, and Electromagnetic Compatibility (EMC) directive 2004/108/EC. In order 

for the customer to maintain compliance with this regulation, high quality shielded cable must be used for interconnection 

to other equipment. Modification of the equipment, other than that expressly outlined by the manufacturer, is not allowed 

under this directive. The user of this equipment shall accept full responsibility for compliance with the LV directive and 

EMC directive in the event that the equipment is modified without written consent of the manufacturer.This declaration 

of conformity is issued under the sole responsibility of Rane Corporation.

Type of Equipment: 

Professional Audio Signal Processing

Brand: 

Rane

Model: 

DC22S

Immunity Results:

  

 

THD+N: 4 dBu, 400 Hz, BW = 20 Hz - 20 kHz

Test 

Description    Specification 

Conditions

RF Electromagnetic Fields Immunity

80 MHz -1000 MHz, 1 kHz AM, 80% depth, 3V/m 

< -80 dB 

80 MHz - 120 MHz

 

<-76 dB 

120 MHz - 155 MHz

 

<-70 dB 

155 MHz - 421 MHz

 

<-52 dB 

421 MHz - 487 MHz

 

<-64 dB 

487 MHz - 736 MHz

 

<-54 dB 

736 MHz - 854 MHz

 

<-75 dB 

854 MHz - 1000 MHz

Conducted RF Disturbances Immunity

150 kHz - 80 MHz, 1 kHz AM, 80% depth, 3V RMS 

< -89 dB 

Power Lines 

 

< -88 dB 

Signal Lines

Magnetic Fields Immunity

50 Hz - 10 kHz, 3.0 - 0.3 A/m 

< -81 dB

Common Mode Immunity:

  

Bandpass re: 4 dBu, 1/3-octave

 

50 Hz - 10 kHz, -20 dBu 

< -78 dB

I, the undersigned, hereby declare that the equipment specified above conforms 

to the Directive(s) and Standard(s) shown above.

Greg Frederick

(Full Name)

Standard(s) to which 

 conformity is declared:

EN60065: 2002/A1:2006/A11:2008/A2:2010/A12:2011

EN55103-1:2009

EN55103-2:2009

EN50581:2012

ENVIRONMENT E2

CE MARK FIRST AFFIXED IN 2009

SERIAL NUMBERS 850000 - 950000

Summary of Contents for DC 22S

Page 1: ...DC22S DYNAMICS CONTROLLER ...

Page 2: ...ain readily operable To completely disconnect this apparatus from the AC mains disconnect the power supply cord plug from the AC receptacle 16 This apparatus shall be connected to a mains socket outlet with a protective earthing connection 17 When permanently connected an all pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the electrical installat...

Page 3: ...ible Pour déconnecter totalement l appareil du secteur débranchez le câble d alimentation de la prise secteur 16 Cet appareil doit être branché à une prise terre avec protection 17 Quand il est branché de manière permanente un disjoncteur tripolaire normalisé doit être incorporé dans l installation électrique de l immeuble 18 En cas de montage en rack laissez un espace suffisant pour la ventilatio...

Page 4: ...ng sleeve set the Input Gain switch to 4 dBu in When driving this input with an unbalanced signal tip sleeve set this switch to 10 dBv out Regardless of the type of Input you might need to set this switch so the INPUT LEVEL LEDs light correctly Now increase the COMPRESSOR RATIO to something useful like 2 1 with the control set at 2 the Ratio is 2 1 at 5 it is 5 1 Adjust the COMPRESSOR THRESHOLD to...

Page 5: ...s or decreases the output gain of each Channel by 15 dB In the center detent gain will be unity LINK switch activates both Compressors when either channel s signal exceeds the set Threshold preserving stereo imaging Switch this ON when using stereo material The channel 1 controls become the Master when this switch is active render ing the channel 2 controls and indicators dead ____________________...

Page 6: ... SUBWOOFER WIRING TIP PIN 2 POSITIVE RING PIN 3 NEGATIVE SLEEVE SIGNAL GROUND PIN 1 CHASSIS GROUND CHANNEL 1 OUTPUT INPUT CHANNEL 2 OUTPUT INPUT MADE IN U S A RANE CORP ME15S COMMERCIAL AUDIO EQUIPMENT 24TJ R 100 240 V 50 60 Hz 7 WATTS INPUT 1 OUTPUT 1 BAL UNBAL BALANCED BALANCED BAL UNBAL 4 dBu 10 dBV MADE IN U S A RANE CORP DC22S WIRING 3 PIN XLR PIN 2 PIN 3 PIN 1 CHASSIS SHIELD 1 4 PHONE BALANC...

Page 7: ...THRESHOLD The threshold is the point at which gain adjustment begins When the input signal is below the threshold the Compressor section acts like a straight wire When the signal is loud enough to cross the Compressor Threshold the compressor is active and turns the volume down Various Threshold points are illustrated in Figure 1 How much it gets turned down is determined by the RATIO control Figu...

Page 8: ...ch to ON and adjust the CHAN NEL 1 COMPRESSOR THRESHOLD and RATIO controls to keep the entire system dynamic range under control Locating the compressor before the equalizer results in correct spectral balance during compression DRIVER PROTECTION To individually limit Low and High drivers in a biamped system connect the Crossover Low Output into one DC22S Input and the High Output into the other D...

Page 9: ...5 Subtract the gain of the amplifier in dB from the answer in step 3 to obtain the correct COMPRESSOR THRESHOLD 6 Set the RATIO to 10 1 NOTES Any change in amplifier sensitivity setting will effect the power limit to the driver If the DC22S is placed just before the amplifier no other system levels will effect the power limit setting EXAMPLE 1 Driver power rating w 100 watts 2 Driver impedance z 4...

Page 10: ... without written consent of the manufacturer This declaration of conformity is issued under the sole responsibility of Rane Corporation Type of Equipment Professional Audio Signal Processing Brand Rane Model DC22S Immunity Results THD N 4 dBu 400 Hz BW 20 Hz 20 kHz Test Description Specification Conditions RF Electromagnetic Fields Immunity 80 MHz 1000 MHz 1 kHz AM 80 depth 3V m 80 dB 80 MHz 120 M...

Reviews: