Manual-2
CP 64 FRONT PANEL
햲
PAGING ZONE ASSIGN
switches select the zone(s) a Page signal is sent to. The RMT position activates the rear panel
RMT ZONE ASSIGN port, allowing the optional PR 2 wired remote to assign the active page Zone(s).
햳
ACTIVE
indicators light when a Page input signal reaches the Page Detect Threshold. Note that a Page is always Active
when its Page Detect Threshold is set to minimum.
햴
ZONE 1 AND ZONE 2 PAGING LEVEL
controls adjust the Paging Level in each Zone.
햵
PROGRAM INPUT LEVEL
“stereo”controls allow independent adjustment of level for each Program Input.
햶
DUCKER OFF/ON
switches turn the Ducker ON or OFF for each Zone.
햷
DUCKER DEPTH
controls
allow setting Ducker Depth (the amount of Program attenuation during a Page) from 50 dB
(ccw) to 6 dB (cw) for each Zone.
햸
ZONE PROGRAM SELECT
switches assign one of four Program Inputs in each Zone.
햹
ZONE RMT
switches, when pushed in, enable the Remotes port for a Zone. This turns control of Zone Level and Zone
Program Select over to the Remotes port. Front panel Zone LEVEL and Zone PROGRAM SELECT controls are inactive
when RMT is selected. Two optional wired ZR 1 remotes may be connected to the Remotes port. An object smaller in
diameter than the switch button is required to engage the RMT switches.
햺
ZONE SIG/OL
indicators show SIGnal present at
−
20 dBu and OverLoad at
+
16 dBu (4 dB before clipping) respectively.
Signal indicators are located pre-EQ and pre-VCA.
햻
ZONE LEVEL
controls
adjust the overall Level for a given Zone.
햽
GRAPHIC EQ
controls are provided for each Zone. Zone 1 controls are “stereo,” with each slider controlling the response
of both Left and Right channels. These controls allow
±
12 dB adjustment of seven ISO center frequencies on two octave
centers.
햾
PWR
indicator lights when the CP 64 is connected to a powered RS 1 power supply.