background image

Description

R&S

®

ZZA-GE23

3

Assembly Instruction, English 5601.5655.02 ─ 03

1

 

Description

The R&S

 

ZZA-GE23 Rack Adapter 2HU is designed for installing units of the suppor-

ted instruments in 19 inch systems. The dimensions of the rackmount kits are designed
according to the 19 inch standard DIN 60297-3-101.

For the installation of the racks in 19 inch cabinets, rails must be used.

The R&S

 

ZZA-GE23 Rack Adapter 2HU is supplied without front handles. However, it

can be retrofitted at any time with handles. Thus, you can define the look of the han-
dles individually according to your wishes. You can use all standard handle bars with
55

 

mm spacing and M4 thread. The outer dimensions should not exceed 65

 

mm. For

the assembly of the handles, use M4x10 countersunk screws.

Suitable examples:

Ganter handle GN 425.6-8-55-EL (available from Ganter)

Rohde handle series ST, ST 08.055.22 (available from Rohde AG, Ettinger, .....)

All necessary screws for mounting are included.

Shipping of instruments built in to the rack is not permitted.

www.allice.de

Allice Messtechnik GmbH

Summary of Contents for ZZA-GE23

Page 1: ...R S ZZA GE23 19 Inch Rack Adapter 2HU Assembly Instruction English 5601565502 Version 03 Æ1ÆÅ2 www allice de Allice Messtechnik GmbH ...

Page 2: ...P814 Four channel 32V 20A 64V 10A Power Supply 800 W 5601 4007 04 R S LCX100 LCR Meter 3629 8856 02 R S LCX200 LCR Meter 3629 8856 03 2022 Rohde Schwarz GmbH Co KG Muehldorfstr 15 81671 Muenchen Germany Phone 49 89 41 29 0 Email info rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co...

Page 3: ...without front handles However it can be retrofitted at any time with handles Thus you can define the look of the han dles individually according to your wishes You can use all standard handle bars with 55 mm spacing and M4 thread The outer dimensions should not exceed 65 mm For the assembly of the handles use M4x10 countersunk screws Suitable examples Ganter handle GN 425 6 8 55 EL available from ...

Page 4: ...trument can be installed in the rack the following are required Remove the appliance feet on the instrument Dismantle the upper and lower covers from the rear bracket Remove appliance feet 1 Remove the screws on the bottom 2 Remove the feet Dismantle the rack adapter 1 Loosen the screws on the rack adapter www allice de Allice Messtechnik GmbH ...

Page 5: ...3 1 2 1 R S ZZA GE23 subrack upper cover 2 R S ZZA GE23 subrack rear bracket 3 R S ZZA GE23 subrack lower cover 2 Dismantle the upper and lower covers from the rear bracket Keep feet with screws well if the instrument is to be operated again as a tabletop unit www allice de Allice Messtechnik GmbH ...

Page 6: ...an circulate through the instruments Reserve enough space on the outsides at least 10 cm to ensure sufficient cooling To install the instrument 1 Place the instrument with the bottom feet position facing up 2 Loosen the four screws at the rear panel partially and slide the two rear brackets over the screws position 3 Tighten the four screws back partially so that mounting of the lower cover can be...

Page 7: ...sembly Instruction English 5601 5655 02 03 6 Place the instrument with the bottom feet position facing down 7 Mount the upper cover over the instrument and tighten the six screws on both top and side of the upper cover www allice de Allice Messtechnik GmbH ...

Reviews: