background image

Key Features

R&S

®

TSMA-BP

8

Getting Started 1177.5885.02 ─ 05

3

 

Key Features

The R&S TSMA-BP Battery Pack Unit allows to enhance the R&S TSMA instru-
ment to a portable measurement solution based on a battery powered system.

Key Features

Power Supply for R&S TSMA in portable applications

Hot-swap support for endless portable mode

In-bay charging feature with smart battery controller

Charging display via LED and monitoring window

Summary of Contents for TSMA-BP

Page 1: ...R S TSMA BP Battery Pack Unit Getting Started Getting Started Version 05 1177588502 ÛÈã2 ...

Page 2: ...12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are trademarks of the owners 1177 5885 02 Version 05 R S TSMA BP The following abbreviations are used throughout this manual R S TSMA BP Battery Pack Unit is abbre viated as R S TSMA BP Battery Pack U...

Page 3: ...2 4 Data Sheets and Brochures 6 2 5 Release Notes and Open Source Acknowledgment OSA 7 3 Key Features 8 4 Preparing for Use 9 4 1 Unpacking and Setting Up the Instrument 9 4 2 Inserting a Battery in the R S TSMA BP Battery Pack Unit 10 4 3 Connecting the R S TSMA BP Battery Pack Unit with R S TSMA 11 4 4 Connecting the R S TSMA BP Battery Pack Unit with External Power Supply 15 5 Operation 17 Inde...

Page 4: ...Contents R S TSMA BP 4 Getting Started 1177 5885 02 05 ...

Page 5: ... and laboratory environments Use the R S TSMA BP Battery Pack Unit only for its designated purpose Observe the operating conditions and perform ance limits stated in the data sheet Where do I find safety information Safety information is part of the product documentation It warns you about the potential dangers and gives instructions how to prevent personal injuries or dam age caused by dangerous ...

Page 6: ...rmation e g safety instructions etc A printed version is delivered with the instrument 2 2 User Manuals and Help Contains the description of all instrument modes and functions Includes the con tents of the getting started manual 2 3 Basic Safety Instructions Contains safety instructions operating conditions and further important informa tion The printed document is delivered with the instrument 2 ...

Page 7: ...e Acknowledg ment OSA The release notes list new features improvements and known issues of the cur rent firmware version and describe the firmware installation The open source acknowledgment document provides verbatim license texts of the used open source software See www rohde schwarz com firmware tsmx Release Notes and Open Source Acknowledgment OSA ...

Page 8: ...s to enhance the R S TSMA instru ment to a portable measurement solution based on a battery powered system Key Features Power Supply for R S TSMA in portable applications Hot swap support for endless portable mode In bay charging feature with smart battery controller Charging display via LED and monitoring window ...

Page 9: ...ting site or test setup can cause damage to the instru ment and to connected devices Ensure the following operating conditions before you switch on the instrument The instrument is dry and shows no sign of condensation The instrument is positioned as described in the following sections Signal levels at the input connectors are all within the specified ranges 4 1 Unpacking and Setting Up the Instru...

Page 10: ...lowing items are included with shipment of the R S TSMA BP Battery Pack Unit R S TSMA BP Battery Pack Unit R S TSMA BP R S No 1523 8009 02 The following items are optional and must be ordered separately Battery for R S TSMA BP Battery Pack Unit R S TSMA BAT R S No 1523 8021 03 Li ion battery RRC2054 15 0 V 3200 mAh 48 0 Wh Charger for batteries R S TSMA BC2 R S No 1523 8015 02 Dual charger for bat...

Page 11: ...ation 4 3 Connecting the R S TSMA BP Battery Pack Unit with R S TSMA In order to use the R S TSMA with the R S TSMA BP Battery Pack Unit the fol lowing steps must be performed The R S TSMA BP Battery Pack Unit may be used only with closed battery cover 1 Attach the R S TSMA base unit with the bottom side see Figure 4 3 on top of the R S TSMA BP see Figure 4 2 Connecting the R S TSMA BP Battery Pac...

Page 12: ...gure 4 2 R S TSMA BP 1 Connectors for R S TSMA base unit Figure 4 3 R S TSMA Base Unit bottom side 1 Connectors for R S TSMA BP 2 Move the R S TSMA base unit to the front side 2 until the connectors are locked Connecting the R S TSMA BP Battery Pack Unit with R S TSMA ...

Page 13: ...t and R S TSMA BP 1 Vertical attachment of R S TSMA base unit bottom with R S TSMA BP top 2 Move T S TSMA base unit to the front side 3 Lock the interconnection using the lock 3 Figure 4 5 Connection of R S TSMA with R S TSMA BP Battery Pack Unit Connecting the R S TSMA BP Battery Pack Unit with R S TSMA ...

Page 14: ...ttery Pack Unit 1 DC IN Connector of R S TSMA Base Unit 2 TSMA Connector R S TSMA BP Battery Pack Unit 3 Interconnection Cable R S TSMA Base Unit R S TSMA BP Battery Pack Unit Note The Interconnection cable 3 is included in the delivery package The cable plugs are marked at both sides with a red spot Figure 4 7 Cable Connected at the DC IN 1 of the R S TSMA this red spot must face upwards at the T...

Page 15: ... TSMA BP Battery Pack Unit with an exter nal power supply The external recharging of the batteries is only allowed via the separate charger R S TSMA BC2 R S No 1523 8015 02 The following steps must be performed 1 Connect the R S TSMA Base Unit 1 with the R S TSMA BP Battery Pack Unit 2 using the connection cable 3 Note In this case the R S TSMA Base Unit will boot immediately 2 Connect the DC OUT ...

Page 16: ...N Connector R S TSMA Base Unit 2 TSMA Connector R S TSMA BP Battery Pack Unit 3 Interconnection Cable R S TSMA Base Unit R S TSMA BP Battery Pack Unit 4 External DC Connector R S TSMA BP Battery Pack Unit 5 Adapter cable TSMA Z1 Battery Pack DC IN 6 DC OUT AC Power Supply TSMA Z1 Connecting the R S TSMA BP Battery Pack Unit with External Power Supply ...

Page 17: ...arate battery charger not included can be used for recharging the batteries In the standard operation mode it is recommended to use always two bat teries with a comparable charging state The batteries will be discharged always in parallel The charging state of the battery is visible on the display 1 Figure 5 1 R S TSMA BAT R S No 1523 8021 03 1 Charging state display The batteries can be exchanged...

Page 18: ... for battery 2 Table 5 1 R S TSMA BP Battery Pack Unit LED states and their meaning LED 1 and LED 2 Color State Comment OFF BAT 1 2 not present blue ON battery charge 100 50 orange ON battery charge 10 50 red ON battery charge 10 buzzer alarm on mainboard green ON For R S TSMA Firmware 03 00 11 00 battery charged For R S TSMA Firmware 03 00 11 00 battery charging external DC con nected green BLINK...

Page 19: ...e R S TSMA instrument The R S TSMA BP Battery Pack Unit without con nected R S TSMA instrument does not display the charging status via the LEDs In order to check the charging status of the batteries without connected R S TSMA remove the batteries from the R S TSMA BP Battery Pack Unit and check the battery internal display ...

Page 20: ...x R S TSMA BP 20 Getting Started 1177 5885 02 05 Index B Brochures 6 D Data sheets 6 G Getting started 6 H Help 6 O Open source acknowledgment OSA 7 R Release notes 7 S Safety instructions 6 U User manual 6 ...