[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:POWer[:STARt]
<Start>
Sets the power for the individual carriers in the defined carrier range. If the com-
mand
:BB:MCCW:EDIT:CARR:POW:STEP
is used to define a step width, the power
entered here applies only to the starting carrier. The power of the remaining carriers is
stepped up or down by the power specified in the
:BB:MCCW:EDIT:CARR:POW:STEP
command.
Parameters:
<Start>
float
Range:
-80 to 0
Increment: 0.01
*RST:
0
Example:
BB:MCCW:EDIT:CARR:POW -50 dB
sets the power of the carrier to -50 dB.
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STARt
<Start>
Selects the first carrier in the carrier range to which the settings with
the
:BB:MCCW:EDIT:CARR:...
commands shall apply.
Parameters:
<Start>
integer
Range:
0 to 8191
*RST:
0
Example:
BB:MCCW:EDIT:CARR:STAR 4
the carrier range starts at carrier 4.
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STATe
<State>
Switches all the carriers in the selected carrier range on or off.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
1
Example:
BB:MCCW:EDIT:CARR:STAT ON
sets all the carriers in the carrier range to ON.
Manual operation:
See
[:SOURce<hw>]:BB:MCCW:EDIT:CARRier:STOP
<Stop>
Selects the last carrier in the carrier range to which the settings with
the
:BB:MCCW:EDIT:CARR:...
commands shall apply.
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...