Remote Control Commands
R&S
®
SMJ100A
640
Operating Manual 1403.7458.32 ─ 14
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal]:TDELay
<ExtTimeDelay>
Specifies the trigger delay for external triggering. The value affects all external trigger
signals.
Parameters:
<ExtTimeDelay>
float
Range:
0 to 688
Increment: 250E-12
*RST:
0
Example:
[:SOURce<hw>]:BB:DM:TRIGger:DELay:UNIT
Manual operation:
See
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal]:RDELay?
Queries the time (in seconds) an external trigger event is delayed for.
Return values:
<ResTimeDelay>
float
Range:
0 to 688
Increment: 250E-12
*RST:
0
Example:
[:SOURce<hw>]:BB:DM:TRIGger:DELay:UNIT
Usage:
Query only
Manual operation:
See
[:SOURce<hw>]:BB:DM:TRIGger[:EXTernal<ch>]:INHibit
<Inhibit>
Sets the number of symbols by which a restart is to be inhibited following a trigger
event. This command applies only in the case of external triggering.
Parameters:
<Inhibit>
integer
Range:
0 to 67108863
*RST:
0
Default unit: symbol
Example:
BB:DM:TRIG:SOUR EXT
selects an external trigger
BB:DM:TRIG:INH 200
sets a restart inhibit for 200 symbols following a trigger event.
Manual operation:
See
SOURce Subsystem
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...