Remote Control Commands
R&S
®
SMJ100A
517
Operating Manual 1403.7458.32 ─ 14
:BLER:SETup:MCOunt
<MCount>
:BERT:SETup:MCOunt
<MCount>
Enters the number of transmitted data bits/data blocks to be checked before the mea-
surement is terminated. With a BER measurement, data that was suppressed by
BERT:SETup:DENable
is not counted. This termination criterion always terminates
the measurement after the specified number of data bits/data blocks. Starting from this
point, the fourth value is output with 1 (= terminate measurement) if the result is quer-
ied with
:BERT|BLER:RES
. If the continuous measurement mode (
BERT|BLER:SEQ
AUTO
) has been selected, the measurement is restarted once the results have been
queried.
Parameters:
<MCount>
integer
Range:
0 to 4294967295
*RST:
1E7
Example:
BERT:SET:MCO 1E6
sets a measurement over 1000000 data bits.
Example:
BLER:SET:MCO 1E3
sets a measurement over 1000 data blocks.
Manual operation:
See
:BLER:SETup:MERRor
<MError>
:BERT:SETup:MERRor
<Merror>
Enters the number of errors to occur before the measurement is terminated. This termi-
nation criterion always terminates the measurement after the specified number of
errors. Starting from this point, the fourth value is output with 1 (= terminate measure-
ment) if the measurement result is queried with
:BERT|BLER:RES
.
Parameters:
<Merror>
integer
Range:
0 to 4294967295
*RST:
100
Example:
BERT:SET:MERR 1E4
sets a measurement over 1000 errors.
Manual operation:
See
:BERT:SETup:RESTart[:STATe]
<State>
Activates/deactivates an external restart of the BER measurement.
Parameters:
<State>
INTernal | EXTernal
*RST:
INTernal
Example:
BERT:SET:REST:STAT INTernal
The external signal restarts the measurement.
BERT and BLER Subsystems
Summary of Contents for SMJ100A
Page 34: ...Preface R S SMJ100A 18 Operating Manual 1403 7458 32 14 Notes on Screenshots...
Page 86: ...Preparing for Use R S SMJ100A 70 Operating Manual 1403 7458 32 14 LXI Configuration...
Page 826: ...Remote Control Commands R S SMJ100A 810 Operating Manual 1403 7458 32 14 UNIT Subsystem...
Page 828: ...Maintenance R S SMJ100A 812 Operating Manual 1403 7458 32 14 Storing and Packing...
Page 844: ...Hardware Interfaces R S SMJ100A 828 Operating Manual 1403 7458 32 14 BERT Connector...