DVB-T2 Configuration and Settings
R&S
®
SMCVB-K164
20
User Manual 1179.0974.02 ─ 02
4.2.2
PLP Info
Access:
► Select "Input Signal > PLP Info".
The tab displays the "PLP <num>" table, that contains individual
information of
up to 20 PLPs.
The information comprises input parameters for each PLP.
Settings:
............................................................................................20
................................................................................................20
Max. Useful Data Rate / Mbit/s
....................................................................... 21
.......................................................................... 21
................................................................................ 21
PLP <num> table
Displays individual parameters for each PLP
<num>
. The table displays information of
up to 20 PLPs with
<num>
ranging from 0 to 19.
PLP Input Format ← PLP <num> table
Displays the input format of each PLP
<num>
for all input sources.
"GFPS/GCS/GSE" require "T2-MI Interface > On".
To edit the input format, select "Input Signal > General > Input Format".
"TS"
Transport stream
"GFPS"
Generic fixed-length packetized stream
"GCS"
Generic continuous stream
"GSE"
Generic stream encapsulation
Remote command:
[:SOURce<hw>]:BB:T2DVb:PLP<ch>:INPut:FORMat
Packet Length ← PLP <num> table
Requires "T2-MI Interface > Off" and "Source > External".
Displays the packet length of the external transport stream in bytes.
If the packet length does not match the specified length, the output signal is erroneous.
"Packet Length > Invalid" is displayed.
Input Signal Settings