Remote Control Commands
R&S
®
SMB100A
414
Operating Manual 1407.0806.32 ─ 21
Options:
R&S
SMB-B5
Manual operation:
See
"Pilot Phase - Stereo Modulation"
[:SOURce]:STEReo:PILot:STATe
<State>
Activates/deactivates the pilot tone generation.
Parameters:
<State>
0 | 1 | OFF | ON
*RST:
OFF
Example:
STER:PIL:STAT ON
activates generation of the pilot tone.
Options:
R&S SMB-B5
Manual operation:
See
"Pilot State - Stereo Modulation"
[:SOURce]:STEReo:PILot[:DEViation]
<Deviation>
Sets the deviation of the pilot tone.
Parameters:
<Deviation>
integer
Range:
0 to 10 kHz
*RST:
6.75 kHz
Example:
SOUR:STER:PIL:DEV 6.75kHz
sets the pilot tone deviation according to standard.
Options:
R&S
SMB-B5
Manual operation:
See
"Pilot Deviation - Stereo Modulation"
[:SOURce]:STEReo:RDS:DATaset
<Dataset>
Selects one of the five data sets provided on the instrument for use in the RDS signal.
Parameters:
<Dataset>
DS1 | DS2 | DS3 | DS4 | DS5
*RST:
DS1
Example:
STER:RDS:DAT DS5
activates use of data set 5 for generation of the RDS signal.
Options:
R&S SMB-B5
Manual operation:
See
"RDS Data Set - Stereo Modulation"
[:SOURce]:STEReo:RDS:STATe
<State>
Activates/deactivates the RDS signal generation. RDS signals can be generated simul-
taneously with MPX and ARI signals.
SOURce Subsystem