Remote Control Commands
R&S
®
SGT100A
382
User Manual 1176.8674.02 ─ 07
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:LOAD
<Filename>
Loads the settings file. If a settings file with the specified name does not yet exist, it is
created. The file extension may be omitted. Only files with the file extension
*.arb_multcarr
will be loaded or created.
Setting parameters:
<Filename>
string
Example:
BB:ARB:MCAR:SETT:LOAD '/var/user/new'
creates settings file
new.arb_multcarr
.
Usage:
Setting only
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:STORe
<Filename>
The command stores the current settings of submenu "Multi Carrier" in a file in the
specified directory. The file extension may be omitted, the files are stored with the file
extension
*.arb_multcarr
.
Setting parameters:
<Filename>
string
Example:
BB:ARB:MCAR:SETT:STOR '/var/user/mcarr2'
stores settings file
mcarr2.arb_multcarr
in the default direc-
tory.
Usage:
Setting only
Manual operation:
See
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:STORe:FAST
<Fast>
Determines whether the instrument performs an absolute or a differential storing of the
settings.
Enable this function to accelerate the saving process by saving only the settings with
values different to the default ones.
Note:
This function is not affected by the "Preset" function.
Parameters:
<Fast>
0 | 1 | OFF | ON
*RST:
1
Manual operation:
See
SOURce Subsystem