Signal Generator Settings
R&S
®
SGT100A
96
User Manual 1176.8674.02 ─ 07
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:PRESet
Save/Recall Frame
Calls the "Save/Recall" dialog.
From the "Save/Recall" menu, the "File Select" windows for saving and recalling the
configurations of the ARB "Multi Carrier" submenu and the "File Manager" can be
called.
Multi carrier configurations are stored as files with the predefined file extension
*.arb_multcarr
. The filename and the directory they are stored in are user-defina-
ble.
The complete settings in the "Multi Carrier" menu are saved and recalled.
"Recall Multi Carrier Settings"
Opens the "File Select" window for loading a saved multi carrier con-
figuration.
The configuration of the selected (highlighted) file is loaded by press-
ing the "Select" button.
"Save Multi Carrier Settings"
Opens the "File Select" window for saving the current multi carrier
signal configuration.
The name of the file is specified in the "filename" entry field, the direc-
tory selected in the "Save Into" field. The file is saved by pressing the
"Save" button.
The "Fast Save" checkbox determines whether the instrument per-
forms an absolute or a differential storing of the settings. Enable this
function to accelerate the saving process by saving only the settings
with values different to the default ones. "Fast Save" is not affected
by the "Preset" function.
"File Manager" Calls the "File Manager" window.
The "File Manager" is used to copy, delete, and rename files and to
create new directories.
Remote command:
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:CATalog?
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:LOAD
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:STORe:FAST
[:SOURce<hw>]:BB:ARBitrary:MCARrier:SETTing:STORe
General Settings
The "General Settings" section is used to configure the multi carrier signal.
Mode
Selects the carrier frequency mode.
"Equidistant Carrier Spacing"
Sets an equidistant carrier spacing. The carrier frequency in the car-
rier table is not configurable.
Baseband