Remote control commands
R&S
®
RTO6
2432
User Manual 1801.6687.02 ─ 05
Suffix:
<m>
.
1..3
1 = A-trigger, 2 = B-trigger, 3 = R-trigger
Available values depend on the selected trigger source. For
input channels CHAN1...4, a trigger sequence can be config-
ured.
For all other trigger sources, only suffix 1 is allowed.
Parameters:
<SourceDetailed>
CHAN1 | CHANnel1 | CHAN2 | CHANnel2 | CHAN3 |
CHANnel3 | CHAN4 | CHANnel4 | EXTernanalog | SBUS | D0 |
D1 | D2 | D3 | D4 | D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 |
D13 | D14 | D15 | LOGIC | MSOB1 | MSOB2 | MSOB3 |
MSOB4 | Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 |
Z2V1 | Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4 | DIFF1 |
DIFF2 | COMMON1 | COMMON2
CHAN1 = CHANnel1, CHAN2 = CHANnel2, CHAN3 = CHAN-
nel3, CHAN4 = CHANnel4
Input channels
EXTernanalog
External analog signal connected to the External Trigger Input.
For this source, only the analog edge trigger is available.
SBUS
Serial bus
D0...D15
Digital channels (option R&S
RTO6-B1)
See also:
Chapter 24.18.4, "Trigger settings for digital signals
LOGIc
Logic combination of digital channels, used as trigger source
(option R&S
RTO6-B1)
MSOB1 | MSOB2 | MSOB3 | MSOB4
Parallel bus (option R&S
RTO6-B1)
Z1V1 | Z1V2 | Z1V3 | Z1V4 | Z1I1 | Z1I2 | Z1I3 | Z1I4 | Z2V1 |
Z2V2 | Z2V3 | Z2V4 | Z2I1 | Z2I2 | Z2I3 | Z2I4
Input channels of R&S
RT-ZVCmulti-channel power probe. Only
available in the A-trigger with trigger type EDGE.
DIFF1 | DIFF2 | COMMON1 | COMMON2
Differential signals
*RST:
CHAN1
Usage:
Asynchronous command
TRIGger<m>:PARallel:TYPE
<Type>
Selects the trigger type to trigger on digital channels and parallel buses.
To trigger on analog channels or the external trigger input, use
.
Mixed signal option (MSO, R&S
RTO6-B1)