Remote control commands
R&S
®
RTO6
2156
User Manual 1801.6687.02 ─ 05
PIDerror
Triggers on any packet identifier error.
CRC5error
Triggers on any CRC5 error event.
CRC16error
Triggers on any CRC16 error event.
BTST
Triggers on any bitstuffing error event (erroneous or missing bit
stuffing sequence, see USB standard).
UNEXpid
Triggers on any unexpected PID error (illegal PID, that is not
allowed in USB low speed and USB full speed protocols, espe-
cially PID's announcing packets such as SPLIT, DATA2, MDATA,
or other noncompliant packets).
SE1error
Triggers on the illegal bus state Single Ended 1 (SE1 = both
lines high).
GLITcherr
Triggers on any glitching error (illegal bit period, see USB stan-
dard for the definition of glitching).
*RST:
ANY
TRIGger<m>:USB:FCONdition
<FrameNoOperator>
Sets the operator to set a specific frame number or a frame number range. The frame
number values are set with
Parameters:
<FrameNoOperator> OFF | ANY | EQUal | NEQual | LTHan | LETHan | GTHan |
GETHan | INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less than or equal, Greater than,
Greater than or equal. These conditions require one frame num-
ber value to be set using
INRange | OORange
In range, out of range. These conditions require a range of
frame number values to be set using
.
*RST:
OFF
TRIGger<m>:USB:FMIN
<FrameNumber>
Specifies the frame number, or sets the the start value of a frame number range.
Parameters:
<FrameNumber>
Protocols