![R&S RTO6 User Manual Download Page 1820](http://html2.mh-extra.com/html/rands/rto6/rto6_user-manual_30646461820.webp)
Remote control commands
R&S
®
RTO6
1820
User Manual 1801.6687.02 ─ 05
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These condition require one identifier pat-
tern to be set with
INRange | OORange
In range / Out of range: Set the minimum and maximum value of
the range with
and
*RST:
EQUal
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CAN:IMAX
<SearchName>,<IdPatternTo>
SEARch:TRIGger:CAN:IMAX?
<SearchName>
Sets the the end value of an identifier range if
is set to
INRange
or
OORange
.
Parameters:
<IdPatternTo>
Numeric or string pattern, see
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CAN:IMIN
<SearchName>,<IdPattern>
SEARch:TRIGger:CAN:IMIN?
<SearchName>
Specifies a message identifier pattern, or sets the the start value of an identifier range.
Parameters:
<IdPattern>
Numeric or string pattern, see
Parameters for setting and query:
<SearchName>
SEARch:TRIGger:CAN:DCONdition
<SearchName>,<DataOperator>
SEARch:TRIGger:CAN:DCONdition?
<SearchName>
Sets the operator to set a specific data pattern or a data pattern range.
Parameters:
<DataOperator>
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan |
INRange | OORange
EQUal | NEQual | LTHan | LETHan | GTHan | GETHan
Equal, Not equal, Less than, Less or equal than, Greater Than,
Greater or equal than. These conditions require one data pattern
to be set with
Protocols