Product description

R&S

®

RT

Z1M

10

Manual 1801.3142.02 ─ 05

2.3.3

 

Dimensions of buffer amplifier and probe

The R&S

 

RT

Z1M high-impedance buffer amplifier and the R&S

 

RT-ZP10 passive

probe have the following dimensions (all values in mm):

Figure 2-3: Dimensions of the R&S

 

RT

Z1M high-impedance buffer amplifier with R&S

 

RT-ZP10

2.4

 

Accessories

2.4.1

 

Supplied accessories

Table 2-2

 lists the accessories supplied with the R&S

 

RT

Z1M high-impedance buffer

amplifier. To order additional probes from Rohde

 

&

 

Schwarz, use the order number

provided in the table.

Table 2-2: Supplied accessories

Item

Quantity

Description

Order number

R&S

 

RT-ZP10 with probe accessories

1

10:1 passive probe

1409.7550.00

2.4.2

 

Service accessories

To order accessories for servicing the probe, contact your Rohde

 

&

 

Schwarz service

center. The following accessories are available:

Table 2-3: Service accessories

Item

Description

R&S RT-ZK1

The service kit is used to calibrate the buffer amplifier, to
do performance tests, and for servicing. The service kit
includes all adapters and accessories to connect the buffer
amplifier to the required measuring instruments.

R&S

 

RT

Z1M Service Manual

The service manual contains a detailed description of the
performance test to verify the specifications, and other
important service procedures.

Accessories

Summary of Contents for RT-Z1M

Page 1: ...R S RT Z1M High impedance buffer amplifier Manual 1801314202 Version 05 B1OZ2...

Page 2: ...Email info rohde schwarz com Internet www rohde schwarz com Subject to change data without tolerance limits is not binding R S is a registered trademark of Rohde Schwarz GmbH Co KG Trade names are tr...

Page 3: ...ervice accessories 10 3 Putting into operation 11 3 1 Connecting the buffer amplifier to the oscilloscope 11 3 2 Identification of buffer amplifier and probe 12 3 3 Connecting the buffer amplifier to...

Page 4: ...Contents R S RT Z1M 4 Manual 1801 3142 02 05 5 4 Calibration interval 18 5 5 Storage and transport 18 5 6 Disposal 18 6 Functional test 20...

Page 5: ...on how to prevent personal injury or damage caused by dangerous situations Printed Safety Instructions for Oscilloscopes and Accessories in many languages is delivered with your Rohde Schwarz oscillo...

Page 6: ...ntegrity The R S RT Z1M can withstand a moderate amount of physical and electrical stress To avoid damage treat the buffer amplifier with care Do not exceed the specified voltage limits Connect the R...

Page 7: ...s e g passive probes current probes and active probes with Rohde Schwarz probe interface The R S RT Z1M provides an integrated R S ProbeMeter which is used for probes without an own R S ProbeMeter Usu...

Page 8: ...e contents 1 Unpack the product carefully 2 Retain the original packing material Use it when transporting or shipping the prod uct later 3 Using the delivery notes check the equipment for completeness...

Page 9: ...f the oscilloscope The interface provides also a USB interface and supply voltages 5 V USB 12 V high power It transmits analog signals and digital data simultane ously The output of the R S RT Z1M is...

Page 10: ...e 2 2 Supplied accessories Item Quantity Description Order number R S RT ZP10 with probe accessories 1 10 1 passive probe 1409 7550 00 2 4 2 Service accessories To order accessories for servicing the...

Page 11: ...h 50 input impe dance only Oscilloscopes that support a 1 M input impedance do not support the buf fer amplifier During usage the probe slightly heats up Warming is normal behavior and not a sign of m...

Page 12: ...buffer amplifier to the DUT Observe the following step order when connecting the components of the measure ment setup Also read and observe the instructions in Chapter 1 Safety information on page 5...

Page 13: ...of the channel to which the buffer amplifier is connected For details refer to the user manual of the oscilloscope Figure 3 2 Offset of R S RT Z1M with R S RT ZP10 signal range 1V Div 3 5 2 AC DC swi...

Page 14: ...precision compared to the oscilloscope s DC accuracy The DC voltage is measured continuously and runs parallel to the time domain measurement of the oscilloscope When the R S ProbeMeter is active the...

Page 15: ...The transfer functions of the gain or attenuation modes are shown in Figure 4 1 The bandwidth of a system specifies the maximum frequency at which a purely sinus oidal signal is still transferred at...

Page 16: ...all 7 modes The rise time of a system is inversely proportional to the bandwidth The following approximation applies BW trise 4 0 The minimum measurable rise time of the whole setup also depends on th...

Page 17: ...e casing is not waterproof Note Do not use cleaning agents Solvents thinners acetone acids and bases can damage the labeling or plastic parts 2 Dry the product completely before using it 5 2 Contactin...

Page 18: ...z ser vice center see Chapter 5 3 Returning for servicing on page 18 5 5 Storage and transport Protect the product against dust Ensure that the environmental conditions e g tem perature range and clim...

Page 19: ...Rohde Schwarz has developed a disposal concept for the eco friendly disposal or recycling of waste material As a manufacturer Rohde Schwarz completely fulfills its obligation to take back and dispose...

Page 20: ...results are influenced by the used oscilloscope Figure 6 1 Functional test 1 Connect the R S RT Z1M to a Rohde Schwarz oscilloscope as described in Chapter 3 1 Connecting the buffer amplifier to the...

Reviews: