![R&S NRT-Z14 Getting Started Download Page 23](http://html1.mh-extra.com/html/rands/nrt-z14/nrt-z14_getting-started_774887023.webp)
Operating concepts
R&S
®
NRT-Z14/44
23
Getting Started 1443.8632.02 ─ 01
5
Operating concepts
............................................................................................. 24
................................................................................................26
5.1
Base unit
See also
Setup
2
3
1
4
5
Figure 5-1: Setup for base unit
1 = signal source
2 = R&S
NRT
‑
Zxx directional power sensor
3 = load
4 = base unit
5 = host interface connector
→
sensor interface
Communication between the R&S
NRT
‑
Zxx directional power sensor and a base
unit is only possible with a baud rate setting of 38400
Bd. This setting is the fac-
tory default that must be restored if the setting was changed. If the R&S
NRT
‑
Zxx
directional power sensor is not recognized by the base unit, check that the baud
rate setting of the R&S
NRT
‑
Zxx directional power sensor is 38400
Bd.
For details on checking and setting the baud rate, see the user manual
> mainte-
nance.
Base unit