background image

Welcome to R&S

 

NGL/NGM

R&S

®

NGL200/NGM200

7

Getting Started 1178.8720.02 ─ 04

2

 

Welcome to R&S

 

NGL/NGM

The one or two-channel power supply series are based on a classical transformer
concept with linear regulators. This concept allows the instrument to achieve
highest accuracy and lowest residual ripple.

The R&S

 

NGL/NGM power supply series feature galvanically isolated, floating

overload and short-circuit proof outputs. When multiple channels are connected in
parallel, higher currents can be achieved. When connected in serial, higher vol-
tages are achievable.

Multi-purpose protection functions are available for each channel which you can
set separately, such as overcurrent protection (OCP), overvoltage protection
(OVP) and overpower protection (OPP). If such a limit is reached, the affected
output channel is automatically turned off and an indicator icon ( ,  ,  ) blinks
on the display. In the case of two-channel power supply (NGL202, NGM202), the
overcurrent protection can be linked to the other channel. In this case, the linked
channel is turned off when the other channel reaches a limit.

Additionally, the R&S

 

NGL/NGM is protected with overtemperature protection

(OTP). This safety feature protects the R&S

 

NGL/NGM from overheating. When

the temperature in the power supply exceeds the OTP limit, the channel outputs
are automatically cut off.

The Arbitrary function allows a freely definable voltage and current sequences
with a timeframe as short as 1 ms. It allows varying the voltage or current during
a test sequence, for example to simulate different charging conditions of a bat-
tery. With "Ramp" function, the R&S

 

NGL/NGM provides the operating condition

to ramp up the supply voltage within a defined timeframe of 10 ms to 10 s.

All R&S

 

NGL/NGM power supplies are equipped with a color TFT display (800

pixels x 480 pixels) and enhanced with touch input capability. The
R&S

 

NGL/NGM comes with a USB and LAN (LXI) interface. Equipped with a

wireless LAN (WLAN) option, you can establish a network connection wirelessly.

The digital I/O interface installed at the rear panel is activated with an option, it
allows a single trigger-in signal to control multi trigger-out signals on the power
supply, providing many possibilities to control outputs and associated devices in
the event when a trigger occurs.

The user manual contains description of the functionalities that the instrument
provides. The latest version is available for download at the product homepage

Summary of Contents for NGL200 series

Page 1: ...R S NGL200 NGM200 Power Supply Series Getting Started Getting Started Version 04 1178872002 D2...

Page 2: ...2019 Rohde Schwarz GmbH Co KG M hldorfstr 15 81671 M nchen Germany Phone 49 89 41 29 0 Fax 49 89 41 29 12 164 Email info rohde schwarz com Internet www rohde schwarz com Subject to change Data withou...

Page 3: ...ic Safety Instructions and the product documentation in a safe place and pass them on to the subsequent users Riesgo de lesiones y da os en el instrumento El instrumento se debe usar de manera adecuad...

Page 4: ...die Produktdokumentation gut auf und geben Sie diese an weitere Benutzer des Produkts weiter Risque de blessures et d endommagement de l appareil L appareil doit tre utilis conform ment aux prescript...

Page 5: ...ument up to date and to be informed about new application notes related to your instrument please send an e mail to the Customer Support Center stating your instrument and your wish We will take care...

Page 6: ...3 3 Unpacking and Checking the Instrument 13 3 4 Setting Up the Instrument 14 3 4 1 Bench Operation 14 3 4 2 Rack Mounting 15 4 Instrument Tour 16 4 1 Overview of Controls 16 4 1 1 Front Panel 16 4 1...

Page 7: ...Contents R S NGL200 NGM200 4 Getting Started 1178 8720 02 04...

Page 8: ...ssages and information on maintenance The online version html format of the user manual provides the complete con tents for immediate display on the internet Basic safety instructions Contains safety...

Page 9: ...ues of the cur rent firmware version and describe the firmware installation The open source acknowledgment document provides verbatim license texts of the used open source software See www rohde schwa...

Page 10: ...ith overtemperature protection OTP This safety feature protects the R S NGL NGM from overheating When the temperature in the power supply exceeds the OTP limit the channel outputs are automatically cu...

Page 11: ...Welcome to R S NGL NGM R S NGL200 NGM200 8 Getting Started 1178 8720 02 04 http www rohde schwarz com product ngl200 for R S NGL and http www rohde schwarz com product ngm200 for R S NGM...

Page 12: ...e instrument casing Read and observe the Basic Safety Instructions delivered as a printed brochure with the instrument Note that the basic safety instructions also contain information on operating con...

Page 13: ...ment results Electromagnetic interference EMI may affect the measurement results To suppress the generated EMI Use suitable shielded cables of high quality for example LAN cables Note the EMC classifi...

Page 14: ...ed that a safe operation is no longer possible the instrument must be shut down and secured against any unintended operation Safe operation can no longer be assumed when Instrument shows visible damag...

Page 15: ...rer without the product s ventilation being obstructed If the manufacturer s specifications are not observed this can result in electric shock fire and or serious personal injury and in some cases dea...

Page 16: ...15 87 lb R S NGL202 R S NGM202 7 3 kg 16 09 lb 7 4 kg 16 31 lb 3 3 Unpacking and Checking the Instrument Unpack the R S NGL NGM power supply carefully and check the content of the package Check the eq...

Page 17: ...instru ment in antistatic wrap to protect it from electrostatic charging Secure the instrument to prevent any movement and other mechanical effects during transportation Delivery package The package...

Page 18: ...3 4 2 Rack Mounting The instrument can be installed in a 19 rack using the rack adapter R S HZN96 P N 3638 7813 02 Proceed according to the installation instructions supplied with the rack adapter Amb...

Page 19: ...s 4 1 1 Front Panel The front panel of the R S NGL NGM is as shown in Figure 4 1 The function keys and navigation controls are located beside the display The various connec tors are located at the rig...

Page 20: ...l keys 2 The menu control keys allow you to access the home window device channel menu window and user key in the instrument For a detailed description on menu control keys see section Menu Controls i...

Page 21: ...screen shots Power key 7 The Power key switches the instrument on and off 4 1 2 Rear Panel Figure 4 2 shows the rear panel of the R S NGL NGM with its connectors Figure 4 2 Rear panel of R S NGL NGM...

Page 22: ...connectors 9 10 Output terminals Either the output terminals at the front panel or those at the back panel can be used Using both terminals at the same time can cause instrument mal function Digital v...

Page 23: ...O connector 15 The Digital I O option R S NGL K103 or R S NGM K103 must be installed for this function to be available in the instrument The specified voltages are 0 V to 24 V for all output pins and...

Page 24: ...hure and safety measures in previous sections are observed Also check if the value on the voltage selector corresponds to the mains voltage 100 V 115 V or 230 V Fuse rating The R S NGL NGM uses the sa...

Page 25: ...utput channels are turned off when the instrument is switched on to prevent connected loads from being damaged unintentionally During startup the R S NGL NGM is loaded with the last saved instrument s...

Page 26: ...t menu see section Out put mode in the User Manual On the display sink mode is shown as negative current 5 1 Setting the Output Voltage and Current 1 Press Home key The R S NGL NGM displays the home w...

Page 27: ...e the same as in source mode green if the current flowing into the R S NGL NGM is below the set current and red if the current is limited to the set value The only visible indication of sink mode is t...

Page 28: ...strument damage caused by cleaning agents Use a dry lint free cloth to clean the product When cleaning keep in mind that the casing is not waterproof Do not use any liquids for cleaning Cleaning agent...

Page 29: ...t 6 Overview of controls Front panel 16 Rear panel 18 P Putting into operation 9 Intended operation 12 Safety 10 Unpacking and checking the instrument 13 R Rear panel AC inlet with fuse holder 19 Chan...

Reviews: