Remote Commands
R&S
®
FSW
906
User Manual 1173.9411.02 ─ 43
CONFigure:GENerator:NPRatio:NOTCh<notch>:CLOCk?
..................................................911
CONFigure:GENerator:NPRatio:NOTCh<notch>:COUNt:CSTate?
.......................................911
CONFigure:GENerator:NPRatio:POWer:LEVel:CSTate?
.................................................... 912
CONFigure:GENerator:NPRatio:POWer:LEVel:OFFSet:CSTate?
........................................ 912
CONFigure:GENerator:NPRatio:RFOutput:STATe:CSTate?
................................................ 913
CONFigure:GENerator:NPRatio:SETTings:NOTCh:UPDate
............................................... 913
CONFigure:GENerator:NPRatio:SETTings:UPDate
........................................................... 913
CONFigure:GENerator:NPRatio:STATe:CSTate?
............................................................... 913
CONFigure:GENerator:NPRatio[:STATe]
...........................................................................914
CONFigure:GENerator:POWer:LEVel
...............................................................................914
CONFigure:GENerator:POWer:LEVel:OFFSet
.................................................................. 914
CONFigure:GENerator:RFOutput[:STATe]
.........................................................................914
CONFigure:GENerator:TARGet:PATH:BB?
....................................................................... 915
CONFigure:GENerator:TARGet:PATH:RF
.........................................................................915
........................................................................................915
CONFigure:SETTings:NPRatio:NOTCh
............................................................................ 915
CONFigure:GENerator:EXTernal:ROSCillator
<ReferenceType>
Selects the source of the generator reference frequency.
Parameters:
<ReferenceType>
EXTernal | INTernal
EXTernal
An external reference is provided via the EXT connectors on the
generator, for example by the R&S
FSW.
INTernal
The internal reference is that of the signal generator itself.
Manual operation:
See
CONFigure:GENerator:FREQuency:CENTer
<Frequency>
Defines the frequency of the signal provided by the signal generator.
Parameters:
<Frequency>
Default unit: HZ
Example:
CONF:GEN:FREQ:CENT 1GHZ
Manual operation:
See
See
CONFigure:GENerator:NPRatio:BB:ARBitrary:WAVeform:SELect?
Queries the ARB waveform file currently used by the signal generator.
Return values:
<ArbWaveform>
Example:
CONF:GEN:NPR:BB:ARB:WAV:SEL?
Usage:
Query only
Configuring and Performing Measurements