Remote Commands
R&S
®
FSW
913
User Manual 1173.9411.02 ─ 43
CONFigure:GENerator:NPRatio:RFOutput:STATe:CSTate?
Queries the state of the generator RF output.
Return values:
<ControlState>
OFF | SUCCessful | ERRor
OFF
Signal generator control off
SUCCessful
Setting successfully applied on the signal generator
ERRor
Control error, for example because a specified value cannot be
applied on the signal generator
Example:
CONF:GEN:NPR:RFO:STAT:CST?
Usage:
Query only
Manual operation:
See
CONFigure:GENerator:NPRatio:SETTings:NOTCh:UPDate
Applies all notch settings to the connected signal generator once.
Example:
CONF:GEN:NPR:SETT:NOTC:UPD
Usage:
Event
Manual operation:
See
"Upload all Notch Settings to Generator"
CONFigure:GENerator:NPRatio:SETTings:UPDate
Applies all generator setup settings to the connected signal generator once.
Example:
CONF:GEN:NPR:SETT:UPD
Usage:
Event
Manual operation:
See
"Upload all Generator Setup Settings to Generator"
CONFigure:GENerator:NPRatio:STATe:CSTate?
Queries the state of the generator notch filter.
Return values:
<ControlState>
OFF | SUCCessful | ERRor
OFF
Signal generator control off
SUCCessful
Setting successfully applied on the signal generator
ERRor
Control error, for example because a specified value cannot be
applied on the signal generator