General Instrument Setup
R&S
®
FSW
720
User Manual 1173.9411.02 ─ 43
When you couple a parameter across all active measurement channels, a change in
the currently selected application is passed on to all other active measurement chan-
nels.
In MSRA mode, the data is captured by the MSRA master only. Thus, parameter cou-
pling is not available for data acquisition parameters. However, it can be useful to cou-
ple time or frequency markers between applications. Thus, you can easily determine
effects that occur at the same time or frequency in different measurement views.
Note that the accuracy of time marker couplings is
±
1 sample.
Synchronizing parameters across all measurement channels
....................................720
Selecting all or no coupling mechanisms
.................................................................... 722
Restoring the default configuration
............................................................................. 722
Synchronizing parameters across all measurement channels
To synchronize a specific parameter, turn on the corresponding function.
Note that you cannot synchronize all parameters at the same time, because some
parameters are interdependent. For example, you cannot synchronize the resolution
and video bandwidth simultaneously, because the video bandwidth depends on the
resolution bandwidth and vice versa.
"Center Frequency"
Synchronizes the center frequency
Remote command:
Synchronizing Measurement Channel Configuration