Remote Commands
R&S
®
FSW
1186
User Manual 1173.9411.02 ─ 43
Example:
CALC:MARK:FUNC:NOIS ON
Switches on the noise measurement.
Manual operation:
See
See
"Switching All Noise Measurement Off"
14.8.3.10
Phase Noise Measurement Marker
The following commands control the phase noise measurement marker function.
Useful commands for phase noise markers described elsewhere
●
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:MAXimum[:
PEAK]
●
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:X
●
CALCulate<n>:DELTamarker<m>:FUNCtion:FIXed:RPOint:Y
Remote commands exclusive to phase noise markers
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:AUTO
............................................. 1186
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:RESult?
.......................................... 1186
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise[:STATe]
........................................... 1187
CALCulate<n>:MARKer<m>:FUNCtion:PNOise:AOFF
.....................................................1188
CALCulate<n>:MARKer<m>:FUNCtion:PNOise:RESult?
..................................................1188
CALCulate<n>:MARKer<m>:FUNCtion:PNOise[:STATe]
...................................................1188
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:AUTO
<State>
This command turns an automatic peak search for the fixed reference marker at the
end of a sweep on and off.
Suffix:
<n>
.
<m>
Parameters:
<State>
ON | OFF | 0 | 1
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:DELT:FUNC:PNO:AUTO ON
Activates an automatic peak search for the reference marker in
a phase-noise measurement.
Manual operation:
See
CALCulate<n>:DELTamarker<m>:FUNCtion:PNOise:RESult?
This command queries the result of a phase noise measurement.
Analyzing Measurements (Basics)