Remote Commands
R&S
®
FSW
1157
User Manual 1173.9411.02 ─ 43
14.8.3.2
General Marker Settings
The following commands control general marker functionality.
Remote commands exclusive to general marker functionality
......................................................................................1157
DISPlay[:WINDow<n>]:MINFo[:STATe]
........................................................................... 1157
CALCulate<n>:MARKer<m>:X:SSIZe
.............................................................................1157
DISPlay[:WINDow<n>]:MTABle
<DisplayMode>
This command turns the marker table on and off.
Suffix:
<n>
.
irrelevant
Parameters:
<DisplayMode>
ON | 1
Turns on the marker table.
OFF | 0
Turns off the marker table.
AUTO
Turns on the marker table if 3 or more markers are active.
*RST:
AUTO
Example:
DISP:MTAB ON
Activates the marker table.
Manual operation:
See
DISPlay[:WINDow<n>]:MINFo[:STATe]
<DisplayMode>
This command turns the marker information in all diagrams on and off.
Suffix:
<n>
.
irrelevant
Parameters:
<DisplayMode>
ON | 1
Displays the marker information in the diagrams.
OFF | 0
Hides the marker information in the diagrams.
*RST:
1
Example:
DISP:MINF OFF
Hides the marker information.
Manual operation:
See
CALCulate<n>:MARKer<m>:X:SSIZe
<StepSize>
This command selects the marker step size mode for
all
markers in
all
windows.
Analyzing Measurements (Basics)