Remote Commands for Bluetooth Measurements (K8)
R&S
®
FSV-K8
82
Operating Manual 1176.7610.02 ─ 02
Example:
For the first steps refer to
chapter 4.14, "Programming Exam-
CONF:BTO:MEAS MCH
Activates the Modulation Characteristics measurement.
CONF:BTO:SWE:COUN 20
Initiates the sweep counter with 20.
... EUT emits bit pattern 10101010
INIT;*WAI
Starts the measurement with synchronization.
CALC:BTO:MCH:DF2:PERC?
Queries the percentage of "in range" measurements.
Usage:
Query only
Mode:
BT
Manual operation:
See
CALCulate<n>:BTOoth:MCHar:RATio?
<Mode>
This command determines the ratio of the average frequency deviations for varying bit
patterns of the payload.
Note:
This command is only available with active Modulation Characteristics measurement
(see
on page 96). With all other measure-
ments this command causes a query error.
Suffix:
<n>
.
irrelevant
Parameters:
<Mode>
MINimum | MAXimum | AVERage
*RST:
-
Example:
For the first steps refer to
chapter 4.14, "Programming Exam-
CONF:BTO:MEAS MCH
Activates the Modulation Characteristics measurement.
CONF:BTO:SWE:COUN 20
Initiates the sweep counter with 20.
... EUT emits bit pattern 1111000
INIT:IMM;*WAI
Starts the measurement with synchronization and erase previ-
ous measurement results.
... EUT emits bit pattern 10101010
INIT:CONM;*WAI
Starts additional measurement with synchronization.
CALC:BTO:MCH:RAT? MIN
Queries the minimum value.
Usage:
Query only
CALCulate subsystem