Remote Control
R&S
®
FSPN
356
User Manual 1179.4363.02 ─ 01
11.6.5
Remote Commands to Configure the Frequency
[SENSe:]ADJust:CONFigure:FREQuency:AUTosearch[:STATe]
.......................................... 356
[SENSe:]ADJust:CONFigure:FREQuency:COUNt
............................................................. 356
[SENSe:]ADJust:CONFigure:FREQuency:LIMit:HIGH
........................................................357
[SENSe:]ADJust:CONFigure:FREQuency:LIMit:LOW
........................................................ 357
[SENSe:]FILTer:LPASs:FREQuency:MANual
.................................................................... 357
....................................................................................... 358
......................................................................................... 358
........................................................................................... 359
............................................................................................359
...................................................................................... 360
..................................................................................360
[SENSe:]ADJust:CONFigure:FREQuency:AUTosearch[:STATe]
<State>
This command turns the automatic (carrier) frequency search on and off.
When you turn of the automatic frequency search, you can define the signal frequency
with
Parameters:
<State>
ON | OFF | 1 | 0
Example:
//Define a signal frequency of 100 MHz
ADJ:CONF:FREQ:AUT OFF
FREQ:CENT 100MHZ
Manual operation:
See
[SENSe:]ADJust:CONFigure:FREQuency:COUNt
<State>
This command turns verification of the signal frequency on and off.
Prerequisites for this command
●
Turn off automatic signal search (
[SENSe:]ADJust:CONFigure:FREQuency:
Parameters:
<State>
OFF | 0
Turns off the frequency counter and measures the frequency
you have entered without verifiying it.
ON | 1
Turns on the frequency counter and verfifies the frequency you
have entered.
*RST:
OFF (automatic signal search is on)
Example:
//Turn off the frequency counter
ADJ:CONF:FREQ:AUT OFF
ADJ:CONF:FREQ:COUN OFF
FREQ:CENT 93.423MHZ
Manual operation:
See
Common Measurement Settings