Spectrum Measurements
R&S
®
ESR
301
User Manual 1175.7068.02 ─ 12
For a list and description of supported detectors see
Filter Type
Opens a submenu to select the filter type.
When measuring Spurious Emissions, using this softkey automatically opens the
"Sweep List" dialog (see
The submenu contains the following softkeys:
●
Normal (3 dB)
●
CISPR (6 dB)
●
MIL Std (6 dB)
Note that the 6
dB bandwidths are available only with option R&S
FSV-K54.
●
Channel
●
RRC
●
5-Pole (not available for sweep type "FFT")
For detailed information on filters see
Chapter 6.2.6.3, "Selecting the Appropriate Filter
Chapter 6.2.6.4, "List of Available RRC and Channel Filters"
Remote command:
[SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE
Res BW CISPR / CISPR (6 dB)
Selects the measurement bandwidth for commercial EMC standards according to
CISPR.
If you select the bandwidth with the "Res BW CISPR" softkey, the R&S
ESR automati-
cally changes the filter type to a 6
dB bandwidth.
For more information see
Chapter 5.2.1, "Measurement Bandwidth"
Remote command:
Filter type:
[SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE
Filter bandwidth:
[SENSe:]BANDwidth|BWIDth[:RESolution]
Res BW Mil Std/ MIL Std (6 dB)
Selects the measurement bandwidths for military EMC standards.
If you select the bandwidth with the "Res BW Mil Std" softkey, the R&S
ESR automati-
cally changes the filter type to a 6
dB bandwidth.
For more information see
Chapter 5.2.1, "Measurement Bandwidth"
Remote command:
Filter type:
[SENSe:]BANDwidth|BWIDth[:RESolution]:TYPE
Filter bandwidth:
[SENSe:]BANDwidth|BWIDth[:RESolution]