![R&S CMW-KM5 Series User Manual Download Page 668](http://html1.mh-extra.com/html/rands/cmw-km5-series/cmw-km5-series_user-manual_3148802668.webp)
LTE Multi Evaluation Measurement
R&S
®
CMW-KM5xx/-KS5xx
668
User Manual 1173.9628.02 ─ 16
<ChannelType>
PUSCh | PUCCh | NONE | DL | SSUB
Detected channel type for the first captured slot
PUSCh
: slot contains only PUSCH
PUCCH
: slot contains only PUCCH
NONE
: slot contains no allocated RBs at all
DL
: downlink slot (only relevant for TDD)
SSUB
: part of special subframe (only relevant for TDD)
<OffsetRB>
Offset of first allocated RB in the first captured slot
Range:
0 to 99
<NoRB>
Number of allocated RBs in the first captured slot
Range:
0 to 100
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.2.70
Options:
R&S CMW-KM502/-KM552 for FDD/TDD
3.5.3.26
Power Monitor Results
The following commands return the power monitor results of the multi evaluation mea-
surement.
FETCh:LTE:MEAS<i>:MEValuation:TRACe:PMONitor[:PCC]?
........................................... 668
READ:LTE:MEAS<i>:MEValuation:TRACe:PMONitor[:PCC]?
.............................................668
FETCh:LTE:MEAS<i>:MEValuation:TRACe:PMONitor:SCC<no>?
......................................669
READ:LTE:MEAS<i>:MEValuation:TRACe:PMONitor:SCC<no>?
....................................... 669
FETCh:LTE:MEAS<i>:MEValuation:TRACe:PMONitor[:PCC]?
READ:LTE:MEAS<i>:MEValuation:TRACe:PMONitor[:PCC]?
Returns the power monitor results for all captured PCC subframes. The number of sub-
frames can be configured, see
.
Return values:
<Reliability>
<Power>
n power values, one per subframe
Range:
-100 dBm to 55 dBm
Default unit: dBm
Example:
See
Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V1.0.15.20
Command Reference