LTE Signaling
R&S
®
CMW-KM5xx/-KS5xx
150
User Manual 1173.9628.02 ─ 16
To configure the neighbor cell entries, press the "Edit" button. The configuration dialog
contains one tab per technology.
Fig. 2-63: Neighbor cell list configuration dialog
Only the enabled entries are broadcasted.
The column "Measurement" is only configurable for enabled entries. It specifies
whether measurement reports for the neighbor cell are requested from the UE.
Received reports are displayed in the main view, see
on page 97. Option R&S CMW-KS510 is required for neighbor cell
measurements.
The individual neighbor cell settings are described in the following.
................................................................................................ 151
Threshold
The configured "Low" reselection threshold value is written into the system information
block element "threshX-Low" defined in 3GPP TS 36.331. It corresponds to the param-
eter "Thresh
X, LowP
" in 3GPP TS 36.304. The resulting threshold value in dB is dis-
played for information.
You can define an individual threshold per technology or a common threshold applica-
ble to all technologies. To apply common thresholds, enable "Threshold > Set for all".
To apply the individual thresholds, disable the parameter.
Remote command:
GUI Reference