CDMA2000 Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
697
User Manual 1173.9511.02 ─ 11
Parameters:
<StopCondition>
NONE | ALEXeeded | MCLexceeded | MFER
NONE
: Continue measurement irrespective of the limit check
ALEXceeded
: Stop if any limit is exceeded
MCLexceeded
: Stop if minimum confidence level is exceeded
MFERexceeded
: Stop if maximum FER is exceeded
*RST:
NONE
Example:
See
Firmware/Software:
V3.0.20
Manual operation:
See
CONFigure:CDMA:SIGN<i>:RXQuality:FERFch:FRAMes
<FERFCHFrames>
CONFigure:CDMA:SIGN<i>:RXQuality:FERSch:FRAMes
<FERSCHFrames>
Defines the number of frames used to calculate FER. Hence it defines the length of a
single shot FER measurement.
Parameters:
<FERSCHFrames>
Range:
1 to 100E+3
Increment: 1
*RST:
1000
Example:
See
Firmware/Software:
V3.0.20
Manual operation:
See
CONFigure:CDMA:SIGN<i>:RXQuality:URATe
<UpdateRate>
Defines update rate for RLP and speech view.
Parameters:
<UpdateRate>
Range:
0.25 s to 2 s
*RST:
1 s
Example:
See
Firmware/Software:
V3.0.10
Manual operation:
See
CONFigure:CDMA:SIGN<i>:RXQuality:RSTatistics
Sets all counters of the RX measurements to zero.
Example:
See
Usage:
Event
Firmware/Software:
V3.0.20
Manual operation:
See
Command Reference