CDMA2000 Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
595
User Manual 1173.9511.02 ─ 11
The examples in this section focus on commands directly related to the packet data
measurement. For general configuration of the signaling application refer to chapter
chapter 4.4.1, "General Configuration"
4.4.3.1
Configuring the Measurement
// *************************************************************
// Configure RX quality measurement: enable results, set update
// rate, MS dormant and inactive timer.
// *****************************************************************************
CONFigure:CDMA:SIGN:RXQuality:RESult:RLP ON
CONFigure:CDMA:SIGN:RXQuality:URATe 2
// *****************************************************************************
// Configure RX quality measurement.
// Set packet call handling.
// *****************************************************************************
CONFigure:CDMA:SIGN:SCONfig:APCalls ACCept
4.4.3.2
Performing the Measurement
Set up an end-to-end connection, see
chapter 4.4.1.7, "Set up a Connection"
on page 590 and DAU's user manual.
// *****************************************************************************
// Reset statistics and return RX quality measurement results.
// *****************************************************************************
CONFigure:CDMA:SIGN:RXQuality:RSTatistics
SENSe:CDMA:SIGN:RXQuality:RLP:DSEGmented?
SENSe:CDMA:SIGN:RXQuality:RLP:DUNSegmented?
SENSe:CDMA:SIGN:RXQuality:RLP:FILL?
SENSe:CDMA:SIGN:RXQuality:RLP:IDLE?
SENSe:CDMA:SIGN:RXQuality:RLP:NAK?
SENSe:CDMA:SIGN:RXQuality:RLP:SYNC?
SENSe:CDMA:SIGN:RXQuality:RLP:ACK?
SENSe:CDMA:SIGN:RXQuality:RLP:SACK?
SENSe:CDMA:SIGN:RXQuality:RLP:BDATa?
SENSe:CDMA:SIGN:RXQuality:RLP:CDATa?
SENSe:CDMA:SIGN:RXQuality:RLP:DDATa?
SENSe:CDMA:SIGN:RXQuality:RLP:REASembly?
SENSe:CDMA:SIGN:RXQuality:RLP:BLANk?
SENSe:CDMA:SIGN:RXQuality:RLP:INValid?
SENSe:CDMA:SIGN:RXQuality:RLP:SUMMary?
SENSe:CDMA:SIGN:RXQuality:RLP:PPPTotal?
SENSe:CDMA:SIGN:RXQuality:RLP:DRATe?
Programming