1xEV-DO Measurements
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
378
User Manual 1173.9511.02 ─ 11
READ:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:AVERage[:
RELative]?
READ:EVDO:MEAS<i>:MEValuation:TRACe:ACP:EXTended:MAXimum[:
RELative]?
Returns the adjacent channel relative power measured in dBc at a series of frequen-
cies. The current, average and maximum traces can be retrieved.
The frequencies are determined by the offset values defined via the commands
and
. All defined
offset values are considered (irrespective of their activation status).
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Return values:
<1_Reliability>
<2_PowOffsetM19>
...
<21_PowOffsetM0>
<23_PowCarrier>
<24_PowOffsetP0> ...
<43_PowOffsetP19>
The power offsets <PowOffsetPn> (<PowOffsetMn>) refer to the
average relative power at the carrier frequency plus (minus) the
frequency offset value number n.
Range:
-100 dBc to 20 dBc
Default unit: dBc
Example:
See
Multi Evaluation: Performing Single-Shot Measurements
Usage:
Query only
Firmware/Software:
V3.2.20
For additional information concerning syntax elements and returned values refer to
Conventions and General Information
.
FETCh:EVDO:MEAS<i>:MEValuation:ACP:CURRent?
FETCh:EVDO:MEAS<i>:MEValuation:ACP:AVERage?
FETCh:EVDO:MEAS<i>:MEValuation:ACP:MAXimum?
READ:EVDO:MEAS<i>:MEValuation:ACP:CURRent?
READ:EVDO:MEAS<i>:MEValuation:ACP:AVERage?
READ:EVDO:MEAS<i>:MEValuation:ACP:MAXimum?
CALCulate:EVDO:MEAS<i>:MEValuation:ACP:CURRent?
CALCulate:EVDO:MEAS<i>:MEValuation:ACP:AVERage?
CALCulate:EVDO:MEAS<i>:MEValuation:ACP:MAXimum?
Return the "Out of Tolerance" result, the "Code Channel Filter Match Ratio" result and
the AT power results.
For the AT power results, the current, average and maximum values can be retrieved.
The "Out of Tolerance" and "Code Channel Filter Match Ratio" results retrieved via the
CURRent
,
AVERage
and
MAXimum
command are identical.
The values described below are returned by
FETCh
and
READ
commands.
CALCulate
commands return limit check results instead, one value for each result listed below.
Command Reference
深圳德标仪器
135-1095-0799