1xEV-DO Signaling
R&S
®
CMW-KG8xx/-KM8xx/-KS8xx
112
User Manual 1173.9511.02 ─ 11
The example above shows that a single shot measurement with an update period of
half the statistics cycle length will always provide valid results. To speed up the single
shot measurement, it is recommendable to reduce the statistics cycle length (defined
by the "Max. Test Packets Sent") and set the update period accordingly.
Remote command:
Assign Views
Enables/disables views (tabs) in the "1xEV-DO RX Measurement" main window. For a
disabled view results are neither displayed nor calculated. Therefore, limiting the num-
ber of assigned views can speed up the measurement.
Remote command:
Measurement Timeout
Defines the timeout for the measurement in remote mode.
For PER and throughput measurements, independent timeout values can be specified
Remote command:
Repetition
Defines how often the measurement is repeated if it is not stopped explicitly or by a
failed limit check.
●
Continuous:
The measurement is continued until it is explicitly terminated; the
results are periodically updated.
●
Single-Shot:
The measurement is stopped after one statistics cycle.
Single-shot is preferable if only a single measurement result is required under fixed
conditions, which is typical for remote-controlled measurements. Continuous mode is
suitable for monitoring the evolution of the measurement results in time and observe
how they depend on the measurement configuration, which is typically done in manual
control. The reset/preset values therefore differ from each other.
For PER and Throughput measurements, independent repetition types can be
selected.
Remote command:
Forward/Reverse Link PER > Stop Condition
Specifies the conditions for an early termination of the measurement:
●
None
: The measurement is performed according to its "Repetition" mode and
"Transport Blocks", irrespective of the limit check results.
GUI Reference
深圳德标仪器