CONFigure:WCDMa:SIGN<i>:CELL:TOUT:OSYNch
<Value>
Sets the "out of synch" timeout value.
This value specifies the time after which the instrument, having waited for a signal from
the connected UE, releases the connection and returns to state Registered.
Parameters:
<Value>
Range:
2 s to 30 s
*RST:
4 s
Default unit: s
Example:
See
Firmware/Software:
V1.0.15.0
Options:
R&S CMW-KS410
Manual operation:
See
CONFigure:WCDMa:SIGN<i>:CELL:TOUT:PREPetitions
<Repetitions>
Specifies the number of paging procedures to be performed if the UE does not answer
paging.
Parameters:
<Repetitions>
Range:
0 to 65535
*RST:
3
Example:
See
Firmware/Software:
V2.0.10
Options:
R&S CMW-KS410
Manual operation:
See
CONFigure:WCDMa:SIGN<i>:CELL:TOUT:PPIF
<Indications>
Number of paging indicators that the R&S
CMW transmits in each PICH frame.
Parameters:
<Indications>
18 | 36 | 72 | 144
*RST:
18
Example:
See
Firmware/Software:
V2.1.30
Options:
R&S CMW-KS410
Manual operation:
See
"Paging Indications per Frame"