Option R&S CMW-KS410 is required.
Remote command:
Data Pattern ← RMC
Bit pattern transmitted as user information on the DTCH: Bit sequence consisting of
zeros (All 0), ones (All 1), 010101... (Alternating), or pseudo-random bit sequences of
variable length (PRBS9, PRBS11, PRBS13, PRBS15).
Remote command:
HSPA
The following parameters configure an HSPA test mode connection. (For background
information see
chapter 2.2.11.3, "High Speed Packet Access (HSPA)"
Option R&S CMW-KS401 is required.
Test Mode Procedure ← HSPA
Selects the connection setup method to be used for "RMC + HSPA" test mode connec-
tions.
Option R&S CMW-KS401 is required.
●
RMC on CS + HSPA 34.108
: When you set up the test mode connection, both the
RMC connection and the HSPA connection are set up.
●
RMC on CS + HSPA (opt)
: When you set up the test mode connection, only the
RMC connection is set up. You can trigger an HSPA connection setup manually
later on if desired (opt = optional).
Thus you can for example test an RMC connection separately and then add an
HSPA connection for additional tests, without releasing the RMC connection in
between.
This value is not available in reduced signaling mode.
Remote command:
Direction ← HSPA
You can enable HSPA in downlink direction only (value HSDPA) or in downlink and
uplink direction (value HSPA).
Option R&S CMW-KS401 is required.
Remote command:
Data Pattern ← HSPA
Selects the bit pattern to be transmitted as user information on the HS-DSCH. The pat-
tern consists of zeros (All 0), ones (All 1), 010101... (Alternating), or pseudo-random bit
sequences of variable length (PRBS9, PRBS11, PRBS13, PRBS15).
Option R&S CMW-KS401 is required.
Remote command:
GUI Reference