![R&S 1444.1190K02 User Manual Download Page 103](http://html1.mh-extra.com/html/rands/1444-1190k02/1444-1190k02_user-manual_774881103.webp)
Remote control commands
R&S
®
NRPxxP
103
User Manual 1179.5760.02 ─ 02
If the pulse period, and thus the duty cycle, cannot be determined, NaN for "not a num-
ber" is returned.
Usage:
Query only
SENSe<Sensor>:TRACe:MEASurement:TRANsition:POSitive:OCCurrence?
Queries the time when the signal passes through the medial reference power level with
rising edge, referenced to the delayed trigger event. Indicates the start point of the first
power pulse within the analysis window.
Usage:
Query only
SENSe<Sensor>:TRACe:MEASurement:TRANsition:SPERiod?
Queries the number of samples per second.
Usage:
Query only
8.9.5.2
Power-related pulse analysis results
Remote commands:
SENSe<Sensor>:TRACe:MEASurement:POWer:AVG?
..................................................... 103
SENSe<Sensor>:TRACe:MEASurement:POWer:HREFerence?
......................................... 104
SENSe<Sensor>:TRACe:MEASurement:POWer:LREFerence?
..........................................104
SENSe<Sensor>:TRACe:MEASurement:POWer:MAX?
.....................................................104
SENSe<Sensor>:TRACe:MEASurement:POWer:MIN?
...................................................... 104
SENSe<Sensor>:TRACe:MEASurement:POWer:PULSe:BASE?
........................................ 104
SENSe<Sensor>:TRACe:MEASurement:POWer:PULSe:DROop?
...................................... 105
SENSe<Sensor>:TRACe:MEASurement:POWer:PULSe:TOP?
.......................................... 105
SENSe<Sensor>:TRACe:MEASurement:POWer:REFerence?
............................................105
SENSe<Sensor>:TRACe:MEASurement:TRANsition:NEGative:OVERshoot?
SENSe<Sensor>:TRACe:MEASurement:TRANsition:POSitive:OVERshoot?
SENSe<Sensor>:TRACe:MEASurement:POWer:AVG?
Queries the average power during the time in which the pulse is active.
Usage:
Query only
Querying measurement results