Chapter 5.5.5, "Time Domain tab"
Source/Receiver Settings
The "RF Power" is the output power of the R&S
ZNA, "IF Bandwidth" and "Average
Factor" determine the operation of the related R&S
ZNA receiver. For a description and
related remote control commands see
Chapter 5.9, "Pwr Bw Avg softtool"
DC Value
Defines how to calculate the DC gain of the DUT (since the R&S
ZNA cannot measure
down to 0 Hz). These parameters are the same settings as for the standard time
domain option R&S
ZNA-K2. For a description and related remote control commands
5.17.2.4
Eye Diag tab
The "Eye Diag" tab is for enabling and configuring the eye diagram and its measure-
ments.
Access:
System – [Applic] > "TDR" > "Eye Diag"
Eye Diagram
The "Eye Diagram" checkbox enables the eye diagram with the current settings
(default or defined in
Remote command:
Eye Diagram ...
that allows to create an eye diagram and to perform
basic settings on the simulated digital signal generator.
Applic softtool